Nikon F6 Repair Manual page 64

Hide thumbs Also See for F6:

Advertisement

DX contact unit/Connecting lever unit/Film detection SW unit/EL roller block unit
・ Assemble the DX contact unit with 2 screws
(#1514), and make soldering bridges. (Fig.1)
・ Assemble the connecting lever unit and the
spring (#576), and clip them together with
#1604. Then hook the spring (#576). (Fig.2)
・ Assemble the film detection SW unit with the
screw (#1510).
・ Assemble the EL roller block unit with 2 screws
(#1508).
#1508×2
1508
B493
EL roller block
unit
Grease: G92KA
B57
Film detection SW unit
- A21 ・
#1712
TA-0003×2
#2158
2158
Connecting lever unit
B572
#576
576
#1510
1510
-
FAA41051-R.3644.A
Fig.1
Soldering bridges
#34
34
#35
35
DX contact unit
#1514×2
Fig.2
Position for attaching
#2158
Position for hooking
the spring (#576)
#1604
Grease: G92KA
1604
Apply to front-back
both sides.
1514

Advertisement

loading

This manual is also suitable for:

41051faa