7-3-2. Near zero comparison/ Near zero
1) NEAR ZERO COMPARISON
GROSS
NET
COMPARISON OFF
ABSOLUTE GROSS
ABSOLUTE NET
2) NEAR ZERO
Operation
1)
Press
MODE
→
Select GROSS/ NET/ COMPARISON OFF/
ABSOLUTE GROSS/ ABSOLUTE NET
2)
Press
MODE
→
7-3-3. Over/Under comparison 1
Select the weight value to make OVER/UNDER COMPARISON.
Select from GROSS/ NET/ COMPARISON OFF.
GROSS
NET
COMPARISON OFF
Operation
Press
MODE
→
Select GROSS/ NET/ COMPARISON OFF
7-3-4. Complete output time
Set the length (time) of outputting the COMPLETE signal (pin 24 of the control connector) upon
completion of weighing.
(input range: 0.0 ~ 9.9)
Operation
Press
MODE
→
Input 0.0 ~ 9.9
Select the weight value to make NEAR ZERO COMPARISON.
Select from GROSS/ NET/ COMPARISON OFF/
ABSOLUTE GROSS/ ABSOLUTE NET.
Comparison is made by gross.
Comparison is made by net.
Comparison is not made.
Comparison is made by absolute-value gross.
Comparison is made by absolute-value net.
Set the near zero comparison weight value.
(input range: 0 ~ 99999)
COMPARISON
NEAR ZERO COMPARISON →
→
COMPARISON
NEAR ZERO →
→
Comparison is made by gross.
Comparison is made by net.
Comparison is not made.
COMPARISON
OVER/UNDER COMPARISON 1
→
COMPARISON
COMPLETE OUTPUT TIME
→
OK
→
7.FUNCTION AS A WEIGHT CHECKER
OK
→
Input 0 ~ 99999
→
OK
→
→
OK
→
53