1.FEATURES OF F805AT-CK
Basically, set "EMPTY COUNT" at 0, and "TAKE IN COUNT" at the maximum value (999).
According to the measuring object weight, set an optimum value to "NEAR ZERO".
For "SAMPLE MODE", select the largest possible value at which the load becomes constant.
(Refer to Fig. 2.)
◇Good example
NET
Near zero
◇Bad example
NET
Near zero
2
Take-in interval
0
Take-in interval
0
With the SAMPLE MODE adjusted, the
position where the weight is flat is
acquired.
(The average of the data of this part is
taken. 50% applies in the figure.)
t
With the SAMPLE MODE set at 100%,
fluctuating data is acquired.
Since the near zero is inappropriate,
the near zero may be applied in a
position different from the proper one.
t
[Figure 2]