Each Code; Final; Over - Unipulse F805AT-CK Operation Manual

Checker scale controller
Table of Contents

Advertisement

7.FUNCTION AS A WEIGHT CHECKER
Long measuring objects
Compared with shorter measuring objects, longer ones cause the entire load to be applied to the load
cell for a shorter time.
Adjust the belt speed, etc., so that a sufficient data count can be obtained.
G
H

7-2. Each Code

Weight checks can be made by assigning code No. to comparison set values, such as FINAL, OVER
and UNDER, and specifying set values to each code No.
Up to 100 code No. can be stored.
Total-comparison-related settings can also be stored by code.

7-2-1. Final

This is the standard for comparison with the results of weighing used upon completion of weighing.
(input range: 0 ~ 99999)
Operation
Press
MODE

7-2-2. Over

When RESULT > FINAL SETTING + OVER SETTING, the status display "HI" lights and the output
signal "HI" turns ON (only while the COMPLETE signal is output).
After the end of the COMPLETE signal output, the above output signal turns OFF, and the status
display is gray-backed.
(input range: 0 ~ 999)
Operation
Press
MODE
50
G'
H'
EACH CODE
(Code No.) →
EACH CODE
(Code No.) →
NET
T
G
T
H
0
FINAL
→ Input 0 ~ 99999
OVER
→ Input 0 ~ 999
(T
T
>
)
G
H
t
OK
OK

Advertisement

Table of Contents
loading

Table of Contents