of the USB
Connect the USB A (male) end
(5) Turn the power switch on the ON side and turn on the power to this device.
The front panel RUN and STOP LEDs
approximately 1 second.
,
* If the LED does not light up
check the connection of the AC
Caution
When connecting various cables, be sure to connect with the power
turned off.
8. Communication settings
The communication environment settings of this device are shown in the table below. Please set the settings on the
computer side according to the table below.
Setting items
baud rate
delimiter
parity
Data Bits
Stop Bits
flow control
9. Command Details
The actuator can be controlled by sending
9-1. Command List
The commands used with this device are shown in the table below.
command
Machine origin return
instruction
Jog Operation Instructions
Relative Movement Pulse
Number Setting Instruction
on your computer
cable to the USB port
turn
on at the same time when power is applied and turn off simultaneously after
adapter
What to set
38400bps
CR+LF
without
8bit
1bit
without
a command
(character string)
Command
characters
H:
Go to the machine origin of the actuator
J:
Specifies the direction of movement of the jog
motion
M:
Specify the relative amount of movement