  • Page 3 This time thank you for having you purchase a Jog controller. ■ About this instruction manual This instruction manual describes the correct usage and functions of the equipment and notes on use. Please read carefully before use to ensure proper operation. Also, keep this manual in a handy place for when you do not understand when using it.
  • Page 4: Precautions For Use

    ■ Precautions for use Please read this instruction manual carefully before use to ensure correct use. Then save it carefully and read it when necessary.。 • This device is used to operate the following Yaskawa stage controller at hand. Do not use for any other purpose.
  • Page 5: Precautions For Install

    • Explains what you should follow. WARNING Do not use in an explosive atmosphere. Never use it in a place where flammable or explosive gas or vapor is present because it may cause an explosion or fire. Do not place in a corrosive atmosphere. Doing so may cause corrosion of the conductor or poor contact of the connector, which may cause malfunction or failure, resulting in a fire.
  • Page 6: Table Of Contents

    Contents ■ About this instruction manual ■ Warranty ■ Repair ■ Contact ■ Precautions for use ■ Safety  Please be sure to observe ■ Precautions for install ■ Cleaning 1. Overview 2. Package Contents 3. Part names and functions 3-1.Panel 3-2.Cable 4.
  • Page 8: Overview

    Purchasers should find that the package contains the items listed below. If anything is missing or damaged, contact us or your distributor. Name Model or specification Quantity Remarks Jog Controller JC-01 Instruction manual This book 3. Part names and functions 3-1.Panel JC-01 Jog Controller...
  • Page 9 (1) Display unit JC-01 Jog Controller The display shows the positioning status, axis name, coordinate value, unit, and error. The error is displayed on the axis where the error has occurred, and all the errors that have occurred are displayed at regular intervals. For the positioning status, axis names, units, and errors, see the instruction manual for the stage controller.
  • Page 10 (2) EMERGENCY switch(Local, Remote, Teach) EMERGENCY Emergency stop switch. Used to stop the stage operation urgently. Can be used in all modes. When the power is supplied to the instrument, pressing the switch locks the instrument to the On side, turns on the lamp in the button, and causes an emergency stop. To cancel, press the switch again to turn it off, and press the Busy Error Cancel key.
  • Page 11 (6) Zero1, Zero2 key(Local, Remote) Zero 1 Zero 2 Set the coordinate value to zero (electric origin setting). Zero1 is the first axis side, and Zero2 is the second axis side. (7) Lock key(Local, Remote, Teach) Lock Long push to unlock Disables key operations other than the EMERGENCY button and this key.
  • Page 12 (12) Jog key(Local, Remote) Move the stage to any position. There are two types of operation: specified pulse amount operation (Jog key once press) and continuous operation (Jog key long press). The pulse amount for the specified pulse amount operation can be set with the Jog Pulse key. The speed during continuous operation can be set with the Jog Speed key.
  • Page 13: 3-2.Cable

    3-2.Cable (1) Connection cable Cable with connector for connecting to stage controller. It cannot be removed from this equipment. It can be connected even when the power to the stage controller is on. However, when removing this equipment from the stage controller, be sure to operate the Disconnect key before disconnecting, or shut off the power supply from the stage controller.
  • Page 14: Specification

    4. Specification These are the specifications for this equipment. 4-1. Basic specifications Item Contents Number of connectable stage controllers Number of control axes Cross JOG operation JOG speed switching JOG command pulse amount switching Stage movement related Mechanical origin return Electric home return Coordinate value zero set Busy error cancel...
  • Page 15: Dimensions

    5. Dimensions JC-01 Jog Controller EMERGENCY Disconnect Teach Long push Select Start/Pause One Step Stop Lock Busy Org 1 Org 2 Zero 1 Zero 2 Error Long push Cancel to unlock EOrg 1 EOrg 2 1000 Sleep Long push to execute...
  • Page 16: Trouble Shooting

    6. Trouble shooting If a problem occurs, check the following. If the remedy does not improve the problem, the instrument or stage controller may be faulty. Unplug the power plug of the stage controller from the outlet and contact our company or our distributor. Contents Possible cause Workaround...
  • Page 17: Update History

    7. Update history Edition Document control number Revision date Supported FV Supported EN MJ-1026-01.01 01.000 ~ 01.00 ~...
  • Page 18 Memo...
  • Page 19: Index

    Disconnect key EMERGENCY switch 3, 4, 8 Electric home return 3, 6 EOrg1, EOrg2 key General specifications iv, 6 JC-01 1, i, 1 Jog controller 1, i, 1 Jog key 2, 4 Jog Pulse key Jog Speed key Lock key...
  • Page 20 SIGMAKOKI CO., LTD. http://www.global-optosigma.com Tokyo Head Office 1-19-9, Midori, Sumida-ku, Tokyo, 130-0021, JAPAN TEL : +81-3-5638-6551 FAX : +81-3-03-5638-6550 E-mail : international@sigma-koko.com Osaka Branch 4-9-28 Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011 TEL : +81-6-6307-4835 FAX : +81-6-6307-4834 Kyushu Sales Office 3-17 Hie-machi, Hakata-ku, Fukuoka 812-0014...

This manual is also suitable for:

Fc-411Fc-414Fc-511Fc-514Fc-611Fc-911

Table of Contents