SECTION III
Service and Technical Manual
COFFEE BOILER
In this menu the temperature of the water inside the coffee boilers can be set.
Menu
Set temperature = 92 °C
[ 60 .. < 92 °C > .. 95 ]
Nom. temperature left = 92 °C
[ 60 .. < 92 °C > .. 95 ]
Nom. temperature right = 92 °C
[ 60 .. < 92 °C > .. 95 ]
Temp. tolerance = 5 °C
[ 0 .. < 5 °C > .. 8 ]
TEA / MILK BOILER
In this menu the temperatures of the tea and milk boiler can be set.
Menu
Set temperature = 80 °C
[ 75 .. < 80 °C > .. 85 ]
Nom. temperature left = 80 °C
[ 75 .. < 80 °C > .. 85 ]
Nom. temperature right = 80 °C
[ 75 .. < 80 °C > .. 85 ]
Temp. tolerance = 2 °C
[ 0 .. < 2 °C > .. 4 ]
3.18
Description
(only available for model AG220)
This value sets the water temperature of the coffee products.
(only available for model AG420)
This value sets the water temperature of the coffee products for the
module on the left hand side.
(only available for model AG420)
This value sets the water temperature of the coffee products for the
module on the right hand side.
This value defines, when coffee products are ready for dispense. As
soon as the coffee boiler reaches the „Nom. temperature" minus
the tolerance value, the machine will be ready for dispensing coffee
products.
Description
(only available for model AG220)
This value sets the water temperature of the tea / milk boiler.
(only available for model AG420)
This value sets the water temperature of the tea / milk boiler for the
module on the left hand side.
(only available for model AG420)
This value sets the water temperature of the tea / milk boiler for the
module on the right hand side.
This value defines, when tea and milk products are ready for dispense.
As soon as the coffee boiler reaches the „Nom. temperature" minus
the tolerance value, the machine will be ready for dispensing tea and
milk products.
REV-6
Black
Technician Level
White
© 2016 by Thermoplan AG, Subject to change