FAULT CODE TROUBLESHOOTING INDEX
1. Continuous Red Flashing Light and Continuous Audible Alarms
2. Green Flashing Light and 15 Second Audible Alarms
3. No LED Light
1. FAULT CODE:
Continuous Red Flashing Light and Continuous Audible Alarms
indicate that the Leak Detector has sensed water in the Leak Tray and will shut
down inlet solenoid.
Possible Reason
Water is present in the Bottom
Tray, causing the leak
detection to trigger.
*Leak Detection is on the Mini
Model only.
Leak in WL2FL Water
Treatment System Mini
WL2FL Manual
Remove the Top Cover and Front Panel. Tip the unit slightly
to drain, dry Bottom Tray completely.
Water is in the bottom of the WL2FL Water Treatment
System. Clear Leak Detection Tray to ensure inside of unit is
dry.
Check for source of leak and fix as necessary.
Flashing Red Light
Solution
Page 50 – Revision AUS-04-23