DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
• Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
• Phillips Screwdriver. Temperature Gauge.
• Water Pitcher or Container to collect water from the faucet
• 3 Litre container or drain basin
• Aquadosa Sanitizer – Or equivalent (3% Hydrogen Peroxide)
• 1/4"O.D. Plastic Tubing, at least 1.5m in length, and assorted 1/4" quick connect fittings.
• Test Strips for measuring sanitizer levels
• TDS Meter (Optional)
1. Unpack the Waterlogic WL2FL Water Treatment Systems and check exterior for damage.
Sanitizing
Sanitize Aquadosa or other approved sanitizing cleaner throughout the cold and or ambient
circuits. Follow all instructions on the sanitizer and flush with fresh water through the faucet
until odour and taste is acceptable.
WARNING!
USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as gloves
and eye protection when using chemicals. Refer to Material Safety Data Sheet for specific
requirements of each chemical product. Take all necessary precautions to prevent sanitizer
from contacting eyes, clothing, and any other surfaces in could damage (carpets).
2. We recommend using Aquadosa sanitizer, 25ml dose is enough to sanitize the machine. See
manufactures instructions for any other sanitizing solution used. Measure and insert 25ml
Aquadosa into the Sanitizing Cartridge. Always ensure sanitizer is compatible with stainless steel
and acetyl plastic.
3. Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of
unit. Turn on water supply.
4. Connect power to WL2FL Water Treatment System. DO NOT TURN ON RED
COMPRESSOR & HEATER SWITCH AT THIS TIME. O=OFF
WL2FL Manual
PRE-DELIVERY PROCEDURES
Page 41 – Revision EU07-07-17
Need help?
Do you have a question about the PUREZZA WL2FL FIREWALL and is the answer not in the manual?