16. Water Streams at an Angle
Water Feed Pressure
Outgoing Flow Rate
WL2FL Manual
Rotate the Bung (Blue Silicone) and the JG fittings a few degrees.
Verify the Incoming Feed with a Pressure Regulator. Should be 2.5-
3bar, Use Pressure Regulator
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.
Verify the outgoing Flow Rate. Should be 1.89 Litres per minute (0.5
gallons per minute) - Firewall Purification.
Dispense water for one minute – should measure 1.89 Litres (0.5
gallons) per minute
Change Flow Restrictor if needed.
Solution
Page 67 – Revision AUS-04-23
Need help?
Do you have a question about the PUREZZA WL2FL FIREWALL and is the answer not in the manual?
Questions and answers