3. Check for any leaks on or around the filters and all
connections. Check for any drips or puddles in the
bottom of the unit. Ensure the leak stop is dry and in the
downward position.
4. Turn the water to the unit on. Water will make its way
through the filter system and up to the Cold Tank, and
flow downward into the Hot Tank. The Cold Tank will fill
halfway first, and then the Hot Tank will begin to fill.
5. Remove the top cover. To do this remove the two screws at the back of the top cover,
slide the cover backwards, and lift away from the unit. Shut off the water supply and
remove the lid of the Cold tank.
6. Add the recommended amount of an approved sanitizing agent to the water
inside the cold tank and gently mix. Allow this mixture to sit in the tank for at
least 10 minutes. After 10 minutes has passed, position a bucket or large
container under the white drain cap on the right side of the unit, behind the
lower front panel. Remove the cap to this drain port and allow the sanitizing
agent and water mixture to drain into the bucket. With a pitcher ready,
dispense cold water until the tank is empty.
7. Once the tanks have completely drained, cap the drain port, and open the
water supply line to allow water to fill the tanks once more. Once full, open
drain again and dispense cold water until the tanks are empty. Repeat this
step one more time for a total of three flushes.
8. Cap the drain port and turn the water supply on.
Place the tank lid back into position and allow the
tanks to fill for the fourth and final time. Once the
tanks are full, and using the touch sensors on the
front panel, dispense both hot and cold water to
ensure flow from tanks.