RESETTING THE HOT TANK OVERHEAT OR HIGH LIMIT SAFETY
Red Compressor/Heater Switch must be in the O=OFF position
1.
Unplug the Power Cord from rear of WL2FL Water Treatment System.
2.
Free Standing Model: Remove the Lower Front Panel by removing the Phillips Head
Screws underneath the Lower Front Panel.
3.
Mini Model: Remove the Side Panel by removing Phillips Head Screws from Side Panel.
Locate the Protective Metal Box on the rear of the hot
4.
tank. As you look through the condenser coils on the
rear of the unit, you will see the hot tank located on the
right-hand side.
From the front of the Water Treatment System, reach
up behind the hot tank and take hold of the protective
metal box covering the thermostat and overheat on the
hot tank.
There are nuts that secure the Protective Metal Box to
the Hot Tank, are loose enough to allow you to remove
5.
the Protective Metal Box.
If the nuts on the metal box are too tight, loosen the
nuts securing the Hot Tank to the upper base of the
WL2FL Water Treatment System unit and lower the
Hot Tank so you can remove the Protective Metal Box.
WL2FL Manual
Page 16 – Revision AU27-04-2023