single machine 20min working time, the maximum recharge time for SPARKULAR
30min.
4. ARM alarming light
ON: DMX connected or wireless remote function ON.
BLINK: DMX armed, ready for firing
OFF: No DMX connection and wireless remote function OFF.
Display Interface
Δ

1. Main Interface:

Background color of DMX area: red means DMX connected.
Background color of TEMP area: red means heating chamber temp. reached setting temp.
machine is ready for firing.
Indicator light status on power switch: flash means machine is heating up, long on means temp.
reached setting temp.

2. Error information

Error information
E0 System IC
E1 Motor condition
E2 Temp. Sensor
E3 P Temp. Over
E4 Time Remain
E5 K Temp. Over
Systematic error
Blower motor, shaft motor or feeding motor error
Temperature sensor is not connected or damaged
Machine shutdown due to chassis over temperature
Firing time is insufficient, please swipe RFID card
Machine shutdown due to heating chamber over temperature