CHAPTER
COMPONENTS
RECOMMENDED ADDITIONAL ARTICLES
Ioniser
Device for the electrostatic discharge of plastic shavings for more cleanliness during the milling
The Ioniser M2 is required for the M2 milling unit. For the M2 Dual milling unit, the Ioniser has to
be installed in both chambers if dry milling is performed in both areas.
Article number Ioniser M2: ZBAC3321
Article number Ioniser M2 Dual Right: ZBAC3321
Article number Ioniser M2 Dual Left: ZBAC3322
ATTENTION: An approach of the chest < 30 cm to the emission tips of the electrode or
the flat contact of several emission tips with the hand should be avoided and can lead to a
temporary switching of the pacemaker into the fault mode.
Teleskoper Orbit
The Teleskoper Orbit and the Blank Repositioner Holder are used to remove and reclamp back in
the orbit at the same position material blanks (Ø 95 mm, Ø 98 mm und Ø 106 mm).
This is useful for adjusting the friction of telescopic works or for milling implant-supported
restorations.
Article number Orbit for milling unit M2 Teleskoper: ZBAC4341
Article number Orbit for milling unit M2 Dual Teleskoper right: ZBAC4361
Article number Orbit for milling unit M2 Dual Teleskoper left: ZBAC4351
26
ZIRKONZAHN – OPERATION AND MAINTENANCE M2 MILLING UNIT COMFORT LINE – VERSION: 19/05/2021
Need help?
Do you have a question about the M2 MILLING UNIT COMFORT LINE and is the answer not in the manual?
Questions and answers