13.6.2
Vertical pedal sensor
VX310082 Pedal sensor vertical
Quantity
Description
1
Pedal sensor vertical
2
M3x12 oval head screw, TORX, ecosyn-fix
1
Cable tie
After the exchange of a pedal sensor, the pedal has to be sealed. For this purpose, additionally order
VX102479 Sealing set (see chapter 13.2)!
2021-03-23 / Rev. 10
STEP 1:
1.
2.
3.
4.
STEP 2:
5.
6.
7.
VV016042
Open pedal housing according to the
procedure described in 13.1.
Remove battery pack according to
13.3.
Disconnect cable from PCB.
Undo the grub screw.
Push out the wave vertical
deflection component from the base
body.
Release spring.
Place rocker in such a way that
access is given to both sensors.
Do not lose the washers when
pushing out the wave vertical de-
flection and reassemble them
after repair.
Lubricate the wave vertical deflec-
tion before reassembling the pe-
dal.
118