From the main master settings screen press the valve button to display the valve screen.
system: Displays the system type. Type 4 (single system) is currently the only available selection.
valve: Contains settings to select the valve model on which the controller is installed.
regen type: Define the regeneration type (time clock, softener metered immediate, softener metered
delayed, filter metered immediate, filter metered delayed, tank sensors).
Note
Depending of the regeneration type selected, following parameters to be set will change.
Note
Adjusting regeneration type may turn set relays OFF depending of the regeneration type
adjust and of the relay set. Any required relays will need to be reprogrammed in the relay
output screen.
Press
to save and pass to the next screen or press
without saving.
70 / 124
Valve
system
valve
regen type
time clock
4
5810
to return to the master settings screen