Manual Regeneration; Operation During A Power Failure - Pentair FLECK 5810 XTR Installer Manual

Hide thumbs Also See for FLECK 5810 XTR:
Table of Contents

Advertisement

8.4.

Manual regeneration

From the home screen, press the regeneration button
Press now to begin a regeneration immediately, or press at regen. time to queue the regeneration for
the programmed regeneration time (2:00 AM default for softeners metered immediate, 12:00 AM
default for filters metered immediate, if day override has not been set). Pressing regeneration
queued again will cancel the manual regeneration.
A
During regeneration, press the button
regeneration, the volume or time will be displayed below the button
8.5.

Operation during a power failure

The XTR includes internal power backup. In the event of power failure, the controller shifts into a
power-saving mode. The controller stops monitoring water usage. The display and motor shut down,
but it continues to keep track of the time and day for a minimum of eight hours.
The system configuration settings are stored in a non-volatile memory and are stored indefinitely with
or without power. After power outage longer than 8 hours, the time of day button may flash indicating
it needs to be reset. Press the button to stop the time of day from flashing and reset time and day if
needed.
If power fails while the unit is in regeneration, the controller will save the current valve position before
it shuts down. When power is restored, the controller will resume the regeneration cycle from the
point where power failed. If power remains off for more than eight hours, upon power restoration the
regeneration is cancelled and the piston returns to service. The next scheduled regeneration button
flashes and a regeneration is queued at the programmed regeneration time (2:00 AM default for
softeners metered immediate, 12:00 AM default for filters metered immediate, if day override has not
been set).
Caution
If power fails during a regeneration cycle, the valve will remain in its current position until
power is restored. The system should include all required safety components to prevent
overflows resulting from a power failure during regeneration.
Ref. MKT-IM-018 / C - 08.06.2018
Installer Manual Fleck 5810 - XTR - Operation
to access the regeneration screen.
Regeneration
now
at regen. time
to immediately advance to the next cycle step. Once in
.
95 / 124