Screen name
Parameters
Media volume
Salt dosage
BLFC size
Capacity
Hardness
Sensor
sensitivity
Valve
Day override
Time driven
Regeneration
time
Reserve
Ref. MKT-IM-018 / C - 08.06.2018
Installer Manual Fleck 5810 - XTR - Programming
Values
3
0.25 to 999 ft
1 to 9999 liters
3
3 to 18 lbs/ft
50 to 290 g/liter
0.125 gpm
0.250 gpm
0.500 gpm
1.000 gpm
1 to 999 999
grams
1 to 9 999 999
grains/degrees * Liter
1 - 199 grains/gallon
1 - 1999 mg/liter
x - x degrees
Not active
OFF - 1 - 99 days
4, 8, 12, 16 and 20
hours
12/24 hours clock
Fixed %
Fixed volume
Weekly reserve
Variable reserve
Notes
Only required on softener metered
regeneration types.
Only required on softener metered systems to
calculate treated water capacity and reserve.
Represents total system capacity between
regenerations.
Only required on softener metered systems to
calculate treated water capacity and reserve.
Represents hardness of untreated water.
Not active
Mandatory for timeclock systems.
Available to be programmed for all
regeneration types.
4 to 20 hours setting available only for the
timeclock systems
Required for time clock and delayed
regeneration types. Set for immediate
regeneration types only when a day override is
also set.
Not available for timeclock system if day
override is set from 4 to 20 hours.
Only available when softener meter delayed
regeneration type is selected.
Selecting fixed % or fixed volume will display
additional configuration options.
Weekly reserve is calculated based on
average day of week's water usage.
Variable reserve is calculated based on
previous day's water usage.
65 / 124