Error Detection; Error Alerts - Pentair FLECK 5810 XTR Installer Manual

Hide thumbs Also See for FLECK 5810 XTR:
Table of Contents

Advertisement

Installer Manual Fleck 5810 - XTR - Troubleshooting

10.1. Error detection

If an error in valve or controller function occurs, an alarm will sound and the home screen will display
the error alert button
Press the alarm button
Press the error alert button
If the display is in sleep mode when an error occurs, the screen will turn on for five minutes. The error
will beep for one second per minute until the error is cleared. If the error is not cleared after five
minutes, the screen will switch to power saving mode and display the error alert button as a screen
saver.

10.2. Error alerts

Note
An error alert appears on the home screen if an error condition is detected. Press the error
alert button
Note
Most error alerts are cleared at regeneration. If the error persists following a regeneration
attempt the appropriate reset and recovery procedure below or contact technical support.
Error screen
display
Optical Sensor
Undesired change
detected in the
optical sensor
114 / 124
and the alarm button
Water treatment
wed
12:01 am
tank refill
rapid rinse
to mute the alarm.
to view information about the error.
to view the error message.
Cause
An undesired optical
sensor state change
occurred.
.
2 d
treatment
backwash
draw
Reset and recovery
Non-critical error. Extra optical sensor pulse detected.
Press the Regeneration button to advance motor to
clear error.
Ref. MKT-IM-018 / C - 08.06.2018