Installer Manual Fleck 5810 - XTR - Programming
format: Contains settings for Language, Units, Assistance Name, Assistance Phone, and Assistance
Interval. See 6.2. Touchscreen controller quick start, page 55 for more information about these
settings.
Note
Differently from what happens if the menu is acceded from the quick start, when acceded
from master setting, push
valve: Contains settings for system, valve, and regeneration type. Plus, depending of the settings,
media volume, salt dosage, BLFC size, capacity, hardness, day override, reserve, volume override and
regeneration time.
regen: Contains settings for regeneration flow and cycles duration.
relay: Contains settings for Aux 1 and Aux 2 relays.
meter: Contains settings for meter types.
settings review: Displays a summary of all programmed settings.
Press the screen navigation arrow at the top right of the screen to navigate to the secondary master
settings screen.
water saver regen.: Set a low water usage regeneration.
remote regen.: Contains settings for triggering a regeneration via a remote input.
cl generation/low salt: Contains settings for chlorine generation and salt alarm.
Mandatory
On the valves of series 5810 and 5812, cl generation/low salt must be set OFF because the
chlorine cell kit managed by the XTR is not available for those valves.
62 / 124
to exit the menu without saving the modifications.
Master Settings
water saver
regen.
cl generation/
remote regen.
low salt
Ref. MKT-IM-018 / C - 08.06.2018