Troubleshooting

Diagnosing switch indicators

Table 18
TABLE 18
Symptom
Power LED is Off
Power LED is Amber
Diag LED is Amber
Link LED is Off

Power and cooling problems

If the power indicator does not turn on when the power cord is plugged in, you may have a problem
with the power outlet, power cord, or internal power supply. However, if the unit powers off after
running for a while, check for loose power connections, power losses or surges at the power outlet,
and use the show chassis command to verify that the temperature is below the shutdown
threshold. If you still cannot isolate the problem, then the internal power supply may be defective.
In this case, contact Technical Support for assistance.

Installation

Verify that all system components have been properly installed. If one or more components appear
to be malfunctioning (such as the power cord or network cabling), test them in an alternate
environment where you are sure that all the other components are functioning properly.
Brocade ICX 6450-C Compact Switch Hardware Installation Guide
53-1002817-02
describes the status of the LEDs and the how to troubleshoot.
Troubleshooting chart
Action
Internal power supply is disconnected.
Check connections between the device, the power cord, and the wall outlet.
Contact Technical Support.
Internal power supply has failed. Contact Technical Support.
The device self test has detected a fault.
Power cycle the device to try and clear the condition. If the condition persists,
contact Technical Support.
Verify that the device and attached device are powered on.
Be sure the cable is plugged into both the device and corresponding device.
Verify that the proper cable type is used and its length does not exceed specified
limits.
Check the adapter on the attached device and cable connections for possible
defects. Replace the defective adapter or cable if necessary.