5.12 Conexionado de PGMs
5.9 Connection of PGMs - Wiring of an LED
Conexionado de un Led
Resistor
Conexionado de PGM como Sirena de Interior
C
NOTE: PGM outputs cannot be completely disabled in installer programming.
To completely disable a PGM output, you must remove all wiring from the PGM
output.

5.10 Siren Output

The siren shall be silenced after the number of minutes programmed for the parti-
tion siren time.
Each partition has its own independent bell time (See commands [159]- [160]). The
panel supervises the siren output in the event of a trip or short circuit condition.

5.11 Periodic Test Report

To ensure that the communication link with the monitoring station is functioning
properly, program the panel to send a test signal periodically.
The test report can be programmed to send signals in minutes, hours or days (see
command [360] option [1] "Test report transmission counters").

5.12 Armed System Follower Test Report

The panel can be programmed to send a follower test report during the time it is
armed. This test can be programmed with a different period than the periodic test
report. Normally, the period of this test is programmed in a shorter time than the
periodic test, thus obtaining a greater check on the panels that are armed (See
command [360] option [2] "Test report transmission counters").

5.13 Manual Test Report

The manual test report is generated by holding down the "0" key on the key for a
period of time longer than three seconds.
5.14 Retransmission of Test Report and/or Network Failure in the event of a
communication failure.
In many cases, when the power goes out in a certain area, the panels start transmi-
tting mains failure to the monitoring station.
If the number of subscribers who need to report such an event is too high, colli-
sions may occur, resulting in communication failures and the event cannot be sent
successfully. To solve this problem, the panel can be programmed to retry to send
the test report or network failure report after a specified time. The retransmission
time is programmed in the command [170] "Re-Transmission Delay of Test and
Network Failure Report on Failure to Send".

5.15 Fire, Medical and Panic Keys

Emergency keys are available on all keypads. These keys must be pressed and held
for three seconds to activate. This delay is designed to prevent activation accidents.
The emergency keys can be configured as audible or silent, independently and for
each keypad (See commands [190]-[197] options [5], [6] and [7]).
Fusible
Rele
Bateria
+
-

5.16 Events Report

The PC-732G® panel stores the last 512 events that occurred on the system. The
Event Memory contains the date and time of each event, along with the zone num-
ber, user number, and any other information pertaining to the event.

5.17 Zone Circuit Response

The normal circuit response time for all zones is 500 milliseconds. The PC-732G
panel will not consider a zone violated unless it is violated for at least 500 millise-
conds.
Zones 1-8 on the PC-732G panel board can be programmed for
a fast circuit response (under 50 mS).
(See commands [110]-[115] option [8] "Response Speed").

5.18 Communication Scenarios

Your system has several means of communication for reporting, among these,
we can highlight the possibility of reporting to different IP addresses, through the
3G-COM-G / 4G-MAX-G and IP-500G modules, sending notifications, etc.
to the users and/or monitoring station, using the 3G-COM-G/ 4G-MAX module.
G. Communication scenarios are an orderly alternative way of organising commu-
nication communications.
The PC-732G® panel has 2 communication scenarios:
Call Scenario N° 1 (Reports with Backups): This scenario has one main output me-
dium and seven different backup possibilities.
(See command [370] "Call Scenario No. 1").
Call Scenario No. 2 (Simultaneous Reporting): This scenario is used for the same
+
-
event to go out by several different means of communication (see command [371]
"Call Scenario No. 2").

5.19 How to operate communication scenarios

For ease of understanding, we will cite different examples of operation:
1) The system shall report the events to the monitoring centre through the
3G-COM-G / 4G-MAX-G module, via the Wifi network of the site, in case of not being
able to report such events, it shall report through the same equipment by means
of the cellular network (mobile data) of the chip, if the equipment has one.
This is a case of Scenario N°1, as it involves the use of backups.
Call scenario No. 1 is programmed in the command [370], its programming
should be: [370] [4][3][5][0][0][0][0][0][0][0].
Position N°3 has the option [5] loaded, which indicates that the backups are termi-
nated.
2) The system shall report the event to the monitoring centre and to the end user
through the 3G-COM-G / 4G-MAX-G module, via the chip's cellular network (mobile
data) simultaneously.
This is a case of Scenario N°2, as it must send an event by various means. Scenario
N°2 is programmed in the command [371], its programming should be:
[371] [0][0][0][1][0][1][0][0].
Position N° 4 has a [1], which enables reporting by mobile data to monitoring, and
position N° 6 enables reporting for the event to reach the end-user via the App.
NOTE: The format "Residential" is valid only for scenario N° 2.

5.20 Reset to Factory Defaults

Sometimes it will be necessary to reset the panel to Factory settings,
To do so, please follow the steps below:
1. Enter Installer Programming.
2. Enter the command [600].
3. Confirm that you wish to reset the panel programming by entering the [1] key.

SECTION 6: Programming wireless devices

The PC-732G® alarm panel has the ability to control up to 24 wireless sensors, 64
keyfobs and 4 PGM-W/MA-220G.
Compatible motion sensors are:
DGW-500 and DGW-500-PET for pet immunity.
The DGM-300 sensor is a wireless magnetic sensor with the ability to accept a
second N/C loop with one or more external magnetic detectors. For more informa-
tion, refer to their respective manuals.
NOTE: Programming of wireless devices can only be performed if has a KPD-
860RF/G-LCD732RF keypad.
11