SECTION 8: Reporting Codes Transmitted in Contact ID and SIA
T ype of Event
Emergency Medical Key
Fire Emergency Key
Police Emergency Key
Disarmed by Coercion
Zone Alarm
Perimeter Alarm
Indoor Zone Alarm
Alarm in Zone 24 Hs
Zone Alarm Input/Output
Tamper
Intruder Verification
Unverified Alarm
Assault
Flooding
Wireless sensor tamper
Keyboard Tamper (4)
Wireless Sensor Monitoring Failure
Network Failure
Low Battery in Panel
System Reset
Change of panel programming and/or keyboard texts
System Shutdown
Power supply Overloaded
Siren circuit fault
Failure in Expander Module (3)
Failure in 3G-COM-G/4G-MAX-G
IP-500 failure
Communication failure
Jamming (3GCOM-G/4G-MAX-G)
Weapon/Disarm
Weapon/Disarm User
Automatic Arming/Disarming
Late to assemble/disassemble
Cancellation
Remote arming/disarming (1)
Key Arming/Disarming
Armed Present
Early Arming/Disarming
Quick Arming/Disarming (2)
Auto-Arming Failure
Recent closure
Zone Bypass
Group Bypass
Manual Test Report
Periodic No-Fault Test Report
Periodic Failure Test Report
Follower Test Report
Clock out of time
Programming login
Programming Output
Clock Programming
Mains Failure Auxiliary Source
Low battery Auxiliary Source
Link failure 3G-COM-G/4G-MAX-G
IP-500 Link failure
Low battery in wireless sensor
Fire Zone Failure
Arming by 3G-COM-G / 4G-MAX-G is reported as user 70. Arming by local cable (PC-Link) is reported as user 75.
IP-500 arming is reported as user 80.
Quick arming/disarming is reported as user 0.
The keypad supervisory fault is identified by the zone/user number. For example, a keypad fault with address 1 is reported with the zone/user field equal
to 1. A keypad with address 8 will be reported with the zone/user field equal to 8.
The monitoring faults of the expander modules are identified through the zone/user field and the reported values are 9 for expander1 to 11 for
expander2.
Auxiliary source supervision fault is reported with zone/user field equal to 12.
3G-COM-G / 4G-MAX-G module failure is reported with the zone/user field equal 13. IP-500 Module failure is reported with zone/user field equal 14.
3G-COM-G / 4G-MAX-G Link failure is reported with zone/user field equal to 1.
IP-500 Link fault is reported with the zone/user field equal to 2.
The keypad tampers are identified in the field "zone/user number" and the reported values are 41 for the keypad with address 1 to 48 for the keypad
with address 8.
Contact ID
New event or assembly
Restoration or Disassembly
1 1AA
1 115
1 12A
1 121
1 13A
1 131
1 132
1 133
1 134
1 137
1 139
1 378
1 122
1 154
1 383
1 145
1 381
1 3A1
1 3A2
1 3A5
1 3A6
1 3A8
1 312
1 321
1 333
1 333
1 333
1 354
1 344
3 4AA
3 4A1
3 4A3
1 4A4
1 4A6
3 4A7
3 4A9
3 441
3 451
3 4A1
1 455
1459
1 57A
1 574
1 6A1
1 6A2
1 6A8
1 6A5
1 626
1 627
1 628
1 3A6
1 342
1 338
1 35A
1 35A
1 384
1 373
New Event or Armed
3 1AA
MA
3 115
FA
3 12A
PA
-
HA
3 13A
BA
3 131
BA
3 132
BA
3 133
BA
3 134
BA
3 137
TA
-
BV
-
BG
3 122
PA
3 154
WA
3 383
TA
3 145
TA
3 381
YX
3 3A1
AT
3 3A2
YT
-
RR
-
LS
-
YX
3 312
YI
3 321
YA
3 333
ET
3 333
ET
3 333
ET
3 354
YC
3 344
HQ
1 4AA
OP
1 4A1
OP
1 4A3
OA
3 4A4
OJ
-
BC
1 4A7
OQ
1 4A9
OS
-
OP
1 451
OK
1 4A1
OP
-
CI
-
CR
3 57A
UB
3 574
BB
-
RX
-
RP
-
RY
-
TX
-
JT
-
LB
-
LS
-
JD
3 342
AT
3 338
YT
3 35A
YC
3 35A
YC
3 384
XT
3 373
FT
SIA
Restoration or Disassembly
MH
FH
PH
-
BH
BH
BH
BH
BH
TH
-
-
PH
WH
TH
TH
YZ
AR
YR
-
-
-
YJ
YH
ER
ER
ER
YK
XH
CL
CL
CA
CJ
-
CQ
CS
-
CK
CL
-
-
UU
BU
-
-
-
-
-
-
-
-
AR
YR
YK
YK
XR
FJ