Command Number 153: Entry Delay No. 3
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Input Delay No. 3
The code must be 3 digits long. Valid values are from 000 to 255 seconds.
Command Number 154: Entry Delay No. 4
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Input Delay No. 4
The code must be 3 digits long. Valid values are from 000 to 255 seconds.
Command Number 155: Exit Delay Partition No. 1
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Exit Delay Partition N° 1
The code must be 3 digits long. Valid values are from 000 to 255 seconds.
Command Number 156: Exit Delay Partition No. 2
Default values ---------------------------------------------------->
Positions------------------------------------------------------------------------->
Digit positions (1) - (3): Exit Delay Partition N° 2
The code must be 3 digits long. Valid values are from 000 to 255 seconds.
Command Number 159: Partition No. 1 Siren Time
Default values ---------------------------------------------------->
Positions------------------------------------------------------------------------->
Digit positions (1) - (3): Partition Siren Time
The code must be 3 digits long. Valid values are from 000 to 255 minutes.
Command Number 160: Partition No. 2 Siren Time
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Partition Siren Time
The code must be 3 digits long. Valid values are from 000 to 255 minutes.
Command Number 163: Time Interval for Crossing Zones
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Time Window for Crossing Zones
The code must be 3 digits long. Valid values are from 000 to 255 seconds.
Note: If you program a time equal to 000, the crossing zones will never generate
an alarm.
Command Number 165: Network Failure/Restore Transmission Delay
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Network Failure/Restore Transmission Delay
The code must be 3 digits long. Valid values are from 000 to 255 minutes.
Note: This delay has a tolerance of +/- one minute.
Command Number 166: Partition No. 1 Inactivity Arming Timeout
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Partition Inactivity Arming Time The code must be 3 digits
long. Valid values are from 000 to 255 hours.
20
0
3
0
1
5
3
(1)
(2)
(3)
0
3
0
1
5
4
(1)
(2)
(3)
0
6
0
1
5
5
(1)
(2)
(3)
0
6
0
1
5
6
(1)
(2)
(3)
0
0
5
1
5
9
(1)
(2)
(3)
0
0
5
1
6
0
(1)
(2)
(3)
0
3
0
1
6
3
(1)
(2)
(3)
0
0
0
1
6
5
(1)
(2)
(3)
0
0
0
1
6
6
(1)
(2)
(3)
Note: If 000 is programmed, the inactivity arming will be cancelled.
Command Number 167: Partition No. 2 Inactivity Arming Timeout
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Partition Inactivity Arming Time The code must be 3 digits
long. Valid values are from 000 to 255 hours.
Note: If 000 is programmed, the inactivity arming will be cancelled.
Command Number 170: Re-Transmission Delay of Test and Fault Reports
Network in the event of a failure to send
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
Digit positions (1) - (3): Re-Transmit Delay Time
The code must be 3 digits long. Valid values are from 000 to 255 minutes.
Note: To cancel this command, it must be programmed with the digits 000
Command Number 172: PGM Pulse Time
Default values ---------------------------------------------------->
Positions ------------------------------------------------------------------------->
The code must be 3 digits long. Valid values are from 000 to 255 seconds.
Command Number 173: Tamper Auto-Arming of Partition with Safe Zone/
Access Control.
Default values --------------------------------------------------->
Positions ------------------------------------------------------------------------->
The code must be three digits long. Valid values are from 000 to 255 seconds.
Note: If 000 is programmed, the function will be cancelled.
Command Number 174: Maximum time of disarmed partition or door open
(Access Control)
Default values ---------------------------------------------------->
Positions------------------------------------------------------------------------->
The code must be three digits long. Valid values are from 000 to 255 seconds.
Note: If 000 is programmed, the function will be cancelled.
Command Number 175: Electrolock pulse time.
Default values --------------------------------------------------->
Positions ------------------------------------------------------------------------->
The code must be three digits long. Valid values are from 000 to 255 seconds.
Command Number 178: PGM Configuration No. 1
Default values -------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2): PGM configuration No. 1
00 = Partition Indication No. 1 Enabled 01 = Partition Indication No. 2 Enabled
02 = Future Use
03 = Future Use
04 = Output Command "Hold"
05 = Output Command "Pulse"
06 = Future Use
07 = Pulse on Alarm Trigger
08 = Siren for Partition No. 1
09 = Siren for Partition No. 2
10 = Future Use
11 = Future Use
12 = Future Use
13 = Mobile Data Communication Failure
14 = Future Use
15 = Battery Failure
16 = Network Failure
17 = Auxiliary Power Failure
18 = Resetting Smoke Sensors
19 = Future Use
20 = Future Use
21 = Pulse in the face of coercion/entrapment
Note: Commands 179 through 181 (PGMS Configuration) are programmed in the
0
0
0
1
6
7
(1)
(2)
(3)
0
3
0
1
7
0
(1)
(2)
(3)
0
0
5
1
7
2
(1)
(2)
(3)
0
3
0
1
7
3
(1)
(2)
(3)
0
0
0
1
7
4
(1)
(2)
(3)
0
0
3
1
7
5
(1)
(2)
(3)
0
1
7
8
(2)