Digit position (7): Keyswitch Activation/Deactivation Report Same options as in
Zone Alarm/Restore Report
Digit position (8): Network Failure/Restore Report Digit position (8): Network Fault/
Restore Report Same Options as Alarm Reporting/Restore in Zones
Command Number 346: Reports 2
Default values ----------------------> 1
3
4
6
Positions -----------------------------> (1)
Digit position (1): Battery Fault/Restore Report
0 = Do Not Report
1 = Reports Using Scenario No. 1
2 = Reports Using Scenario No. 2
Digit position (2): Future Use
Digit position (3): Future Use
Digit position (4): Fault Report/Restore Sensor-RF monitoring Same options as in
Fault Report/Battery Restore.
Digit position (5): Sensor -RF Low Battery Report Same options as Battery Fault/
Restore Report
Digit position (6): Programming Input / Output Report Same options as Battery
Fault/Restore Report
Digit position (7): Clock Programming Report Same options as Battery Fault/Res-
tore Report Digit position (8): Keypad Tamper / RF Sensor Report Same options as
Battery Fault/Restore Report
Digit position (8): Keypad Tamper / RF Sensor Report Same options as Battery
Fault/Restore Report
Command Number 347: Reports 3
Default values -----------------------> 1
3
4
7
Positions -----------------------------> (1)
Digit position (1): Periodic Test Report Report (Manual and Automatic)
0 = Do Not Report
1 = Reports Using Scenario No. 1
2 = Report Using Scenario No. 2
Digit position (2): Follower Test Report Report Same options as in Periodic Test
Report Report
Digit position (3): Auxiliary Failure
Same options as in Periodic Test Report Report
Digit position (4): Auto Arming/Auto Disarming Report Same options as in Periodic
Test Report Report Report
Digit position (5): Auto Arming Inactivity Timeout Report or no movement Same
options as Periodic Test Report Report
Digit position (6): Manual Test Report Same options as in the Periodic Test Report
Report
Digit position (7): Fault Report Siren Output Same options as in the Periodic Test
Report Report Report
Digit position (8): Fault Report Keypad / Expander / Auxiliary Source supervision
and Jamming Same options as in Periodic Test Report Report
Command Number 350: Future Use.
Command Number 360: Test Report Transmission Counters
Default values ------------------------------------------->
3
Positions--------------------------------------------------->
Digit position (1): Periodic Test Transmission Counter
0 = Counter in Minutes
1 = Counter in Hours
2 = Counter in Days
Digit position (2): Test Transmission Counter Tracker
0 = Counter in Minutes
1 = Counter in Hours
2 = Counter in Days
Digit Position (3): Reserved for Future Use
0 = Future Use
1 = Future Use
2 = Future Use
Digit Position (4): Reserved for Future Use
0 = Future Use
1 = Future Use
2 = Future Use
Command Number 361: Telephone Test Report Time Interval
Default values ----------------------------------------------------->
26
1
1
1
1
1
(2)
(3)
(4)
(5)
(6)
1
1
1
1
(2)
(3)
(4)
(5)
(6)
1
0
6
0
(1)
(2)
0
Positions -------------------------------------------------------------------------->
Digit positions (1) - (3): Time interval of the Telephone Test Report
The command must be 3 digits long. Valid values are from 000 to 255
Note: Set 000 to cancel the Periodic Test report.
1
1
Command Number 362: Follower Test Report Time Interval
Default values ---------------------------------------------------->
(7)
(8)
Positions -------------------------------------------------------------------------->
Digit positions (1) - (3): Time interval of the Tracker Test Report
The command must be 3 digits long. Valid values are from 000 to 255
Command Number 370: Call Scenario No. 1 (Reports with Backups)
Default values ----------------------> 0
Positions -----------------------------> (1)
Digit position (1): Main output medium
0 = Future Use
1 = Future Use
2 = Future Use
3 = Reports to Mobile Data Monitoring (3G-COM-G / 4G-MAX-G)
4 = Report to WiFi monitoring
5 = End of Backups
Digit position (2): First Main Output Media Backup
Digit position (3): Second Main Output Media Backup
1
1
1
Digit position (4): Third Main Output Media Backup
Digit position (5): Fourth Main Output Media Backup
Digit position (6): Fifth Main Output Media Backup
(7)
(8)
Digit position (7): Sixth Main Output Media Backup
Digit position (8): Seventh Main Output Media Backup Same options as in Main
Output Media
Command Number 371: Call Scenario No. 2 (Simultaneous Reporting)
Default values ----------------------> 0
Positions------------------------------> (1)
Digit position (1): Future Use
0 = Future Use
1 = Future Use
Digit position (2): Future Use
0 = Future Use
1 = Future Use
Digit position (3): Transmit via SMS - Residential
0 = Disabled
1 = Enabled
Digit position (4): Reports to Mobile Data Monitoring (3G-COM-G / 4G-MAX-G)
0 = Disabled
1 = Enabled
Digit position (5): Report to WiFi monitoring (IP-500G)
0 = Disabled
0
0
1 = Enabled
Digit position (6): IP-Residential (IP-500G)
0 = Disabled
(3)
(4)
1 = Enabled
Digit position (7): Future Use
0 = Future Use
1 = Future Use
Digit position (8): Future Use
0 = Future Use
1 = Future Use
Command Number 400: Zone Assignment for Wireless Sensor in Memory Loca-
tion No. 1
Default values--------------------------------------------------------------------------------> 0
Positions ---------------------------------------------------------------------------------------> (1)
Digit positions (1) - (2): Zone number for sensor recorded in memory location 1
The command must be 2 digits long. Valid values are from 00 to 32
Note: Commands 401 through 423 (Zone Assignment for Wireless Sensors) are
programmed in the same manner as Command No. 400.
Important: Only keypads with Address 1, 2, 3, and 4 function as receivers.
2
4
3
3
5
0
3
7
0
(2)
(3)
0
0
3
7
1
(2)
(3)
6
1
(1)
(2)
(3)
0
0
0
6
2
(1)
(2)
(3)
0
0
0
0
0
(4)
(5)
(6)
(7)
(8)
0
0
0
0
0
(4)
(5)
(6)
(7)
(8)
0
4
0
0
(2)