same manner as Command No. 178.
Default settings of PGMs 2-4: PGM No. 2 indicates Partition No. 2. Activated.
Command Number 179: PGM Configuration No. 2
Default values -------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Command Number 182: PGM-W Configuration No. 1
Default values ------------------------------------------------------------------------------>
Positions -------------------------------------------------------------------------------------> (1)
Digit position (1)- (2):
00 = Future Use
01 = Future Use
02 = Future Use
03 = Future Use
04 = Output Command "Maintained".
05 = Output Command "Pulse".
06 = Future Use
07 = Future Use
08 = Siren for Partition No. 1
09 = Siren for Partition No. 2
10 = Future Use
11 = Future Use
Note: Values from 12 to 20: Future Use.
Note: Commands 183 through 185 (PGM-Ws Configuration) are programmed in
the same manner as Command No. 182.
Command Number 183: PGM-W Configuration No. 2
Default values ------------------------------------------------------------------------------->
Positions -------------------------------------------------------------------------------------> (1)
Command Number 184: PGM-W Configuration No. 3
Default values --------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Command Number 185: PGM-W Configuration No. 4
Default values ------------------------------------------------------------------------------>
Positions -------------------------------------------------------------------------------------> (1)
Command Number 190: Keyboard Partitioning and Attribute Assignment No. 1
Default values ------>
1
9
0
Positions ---------------------------> (1)
Digit position (1): Partition Assignment No.1
0 = Keypad Does Not Control Partition No. 1
1 = Keypad Controls Partition No. 1
Digit position (2): Partition Assignment No. 2
0 = Keypad Does Not Control Partition No. 2
1 = Keypad Controls Partition No. 2
Digit position (3): Future Use
0 = Future Use
1 = Future Use
Digit position (4): Future Use
0 = Future Use
1 = Future Use
Digit position (5): Fire Key
0 = Silent
1 = Audible
Digit position (6): Panic Key
0 = Silent
1 = Audible
Digit position (7): Emergency Medical Key
0 = Silent
1 = Audible
Digit position (8): Keypad Tamper
0 = Disabled
1 = Enabled
Note: Commands 191 to 197 (Partition Assignment and Keypad Attributes) are
programmed in the same way as Command No. 190.
1
7
9
1
8
2
1
8
3
1
8
4
1
8
5
1
0
0
0
1
0
(2)
(3)
(4)
(5)
(6)
Command Number 191: Keyboard Partition and Attribute Assignment No. 2
Default values -----------------------> 1
1
Positions ---------------------------> (1)
1
Command Number 192: Keyboard Partitioning and Attribute Assignment No. 3
(2)
Default values -----------------------> 1
1
Positions---------------------------> (1)
0
0
Command Number 193: Partition Assignments and Keyboard Attributes No. 4
(2)
Default values -----------------------> 1
1
Positions ---------------------------> (1)
Command Number 194: Keyboard Partitioning and Attribute Assignment No. 5
Default values -----------------------> 1
1
Positions ---------------------------> (1)
Command Number 195: Partitioning and Keyboard Attribute Assignment No. 6
Default values -----------------------> 1
1
Positions ---------------------------> (1)
Command Number 196: Partitioning and Keyboard Attribute Assignment No. 7
Default values -----------------------> 1
1
0
0
Positions ---------------------------> (1)
(2)
Command Number 197: Keyboard Partitioning and Attribute Assignment No. 8
Default values------------------------> 1
1
0
Positions ---------------------------> (1)
(2)
Command Number 200: Keypad Zone Assignment No. 1
Default values -------------------------------------------------------------------------------> 0
0
0
Positions -------------------------------------------------------------------------------------> (1)
(2)
Digit position (1)- (2): Keypad Zone Assignment No. 1
The code must be 2 digits long. Valid values are 00 to 32.
With the value [00] the keypad zone will be bypassed.
0
0
Note: Commands 201 to 207 (Keypad Zone Assignment) are programmed in the
same way as Command No. 200.
(7)
(8)
Command Number 201: Keypad Zone Assignment No. 2
Default values -------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
Command Number 202: Keypad Zone Assignment No. 3
Default values ------------------------------------------------------------------------------> 0
Positions-------------------------------------------------------------------------------------> (1)
Command Number 203: Keypad Zone Assignment No. 4
Default values -------------------------------------------------------------------------------> 0
Positions -------------------------------------------------------------------------------------> (1)
0
0
0
9
1
(2)
(3)
(4)
0
0
0
9
2
(2)
(3)
(4)
0
0
0
9
3
(2)
(3)
(4)
0
0
0
9
4
(2)
(3)
(4)
0
0
0
9
5
(2)
(3)
(4)
0
0
0
9
6
(2)
(3)
(4)
0
0
0
9
7
(2)
(3)
(4)
2
2
2
2
1
0
0
0
(5)
(6)
(7)
(8)
1
0
0
0
(5)
(6)
(7)
(8)
1
0
0
0
(5)
(6)
(7)
(8)
1
0
0
0
(5)
(6)
(7)
(8)
1
0
0
0
(5)
(6)
(7)
(8)
1
0
0
0
(5)
(6)
(7)
(8)
1
0
0
0
(5)
(6)
(7)
(8)
0
0
0
(2)
0
0
1
(2)
0
0
2
(2)
0
0
3
(2)
21

Advertisement