Tank truck level gauge

Advertisement

Tank Truck Level Gauge
Enhanced Alarm Feature Version
DATE INSTALLED: _______________________________________________________________________________
UNIT NUMBER: _________________________________________________________________________________
COMPARTMENT: _______________________________________________________________________________
DISPLAY CALIBRATION UNITS (e.g. inches, gallons): ___________________________________________
MINIMUM TANK READOUT: ___________________________________________________________________
MAXIMUM TANK READOUT: ___________________________________________________________________
ALARM POINT (IF APPLICABLE): ________________________________________________________________
SPILLSTOP EMPTY POINT (IF APPLICABLE): ____________________________________________________
SPILLSTOP HORN POINT (IF APPLICABLE): _____________________________________________________
SPILLSTOP SHUTDOWN POINT (IF APPLICABLE): ______________________________________________
AUTOMATIC ALARM:
CANADA
Garnet Instruments
286 Kaska Road
Sherwood Park, AB T8A 4G7
MODEL 808-P2
IMPORTANT OPERATOR INFORMATION
WARNING LEVEL: ____________________________________________________
EMPTY LEVEL: ________________________________________________________
USA
Garnet US Inc.
5360 Old Granbury Road
Granbury, TX 76049
TM
garnetinstruments.com
1-800-617-7384

Advertisement

Table of Contents
loading

Summary of Contents for Garnet SeeLevel Special 808-P2

  • Page 1 SPILLSTOP HORN POINT (IF APPLICABLE): _____________________________________________________ SPILLSTOP SHUTDOWN POINT (IF APPLICABLE): ______________________________________________ AUTOMATIC ALARM: WARNING LEVEL: ____________________________________________________ EMPTY LEVEL: ________________________________________________________ CANADA garnetinstruments.com Garnet Instruments Garnet US Inc. 1-800-617-7384 286 Kaska Road 5360 Old Granbury Road Sherwood Park, AB T8A 4G7 Granbury, TX 76049...
  • Page 2: Table Of Contents

    GARNET Tank Truck Level Gauge Enhanced Alarm Feature Version MODEL 808-P2 Table of Contents CHAPTER 1 - OVERVIEW .....................3 CHAPTER 2 - ENHANCED ALARM FEATURES VERSION .........4 CHAPTER 3 - GAUGE DESCRIPTION ...............6 CHAPTER 4 - UNIQUE FEATURES ................9 CHAPTER 5 - SENDER BAR LIMITS OF RESISTIVITY ........11 CHAPTER 6 - 808-P2 INSTALLATION GUIDE .............
  • Page 3: Chapter 1 - Overview

    CHAPTER 1 - OVERVIEW Congratulations on purchasing the Garnet Instruments SeeLeveL Special ™ Tank Truck Level Gauge model 808-P2. The 808-P2 represents the state of the art in liquid level measurement equipment for transport applications. The 808-P2 is designed for reliable, accurate level measurement of sour or sweet crude oil, chemicals, acids, water, condensate, gasoline, or diesel fuel.
  • Page 4: Chapter 2 - Enhanced Alarm Features Version

    CHAPTER 2 - ENHANCED ALARM FEATURES VERSION he 808-P2 has some enhancements over the 808PA series. It uses new technology in the display to provide a number of new features: 1. The calibration memory has been changed to a flash memory device which is much more secure and does not require power to maintain the memory contents.
  • Page 5 8. The display has the ability to drive a remote transmitter for applications which require the transfer of the data from the gauge to another piece of equipment. 9. The density of the product can be entered into the gauge to enhance measurement accuracy.
  • Page 6: Chapter 3 - Gauge Description

    The display has a SpillStop transmitter for direct connection to a Garnet 815 SpillStop ™ or 815-UHP SpillStop Ultra™ controller. The transmitter operates in accordance with the programmed alarm points 1, 2, and 3.
  • Page 7 The display has two alarm outputs, one is a horn warning and the other is a shutdown. These outputs are transistors which complete a circuit to ground when turned on. To take advantage of the automatic warning and shutdown capability, program the alarms as follows: Not used here, for SpillStop applications only Program as a shutdown alarm where you want the warning horn to...
  • Page 8 Installation of the gauge consists of cutting a hole in the top of the tank and welding in a 1 inch coupler, and welding an anchor assembly to the bottom of the tank. The sender bar is cut to length, the end is sealed, and it is inserted from the top of the tank and fastened at the top with a compression fitting.
  • Page 9: Chapter 4 - Unique Features

    CHAPTER 4 - UNIQUE FEATURES he SeeLeveL gauge has been designed for maximum ease of installation and servicing, and for best operational features. The anchor at the bottom of the tank provides a shock mount for the float, and holds the float in place while the bar is removed so no tank entry is required for sender bar replacement.
  • Page 10 GENERAL MECHANICAL ASSEMBLY HEAD (INSTALLED HEIGHT LESS THAN 5 INCHES ABOVE THE TOP OF THE TANK) COMPRESSION FITTING 1” COUPLER 1/4” AIR LINE CONTAINING FIBER TANK CUTAWAY OPTIC INTERCONNECT CABLE STAINLESS STEEL SENDER BAR TAPER ALLOWS DEBRIS TO SLIDE OFF FLOAT ANCHOR SUPPORT WIRES FOR OPTIONAL ELECTRICAL HOOKUPS FOR 12 VDC BACK LIGHT...
  • Page 11: Chapter 5 - Sender Bar Limits Of Resistivity

    CHAPTER 5 - SENDER BAR LIMITS OF RESISTIVITY he temperature of the product being transported should be limited to approximately +90°C (+194°F). Damage to the float and sender bar can occur if this value is exceeded. The tube used in the manufacturing of the sender bar is seamless 316 stainless steel.
  • Page 12 FLUID COMPATIBILITY CHART for metal threaded ttings sealed with Loctite Sealants ® LIQUIDS, SOLUTIONS & SUSPENSIONS Bagasse Fibers......Chlorobenzene Dry ....Ferrous Chloride ...... Ion Exclusion Glycol ....Nickel Chloride......LEGEND: Barium Acetate ......Chloroform Dry......Ferrous Oxalate......Irish Moss Slurry...... Nickel Cyanide ......
  • Page 13 FLUID COMPATIBILITY CHART for metal threaded ttings sealed with Loctite Sealants ® & River Water....... Sodium Sulfate ......Toluene........Acetylene ........LEGEND: Road Oil ........Sodium Sul de ......p-Toluene Sulfonic Acid .... † Acid & Alkali Vapours ....All Loctite ®...
  • Page 14: Chapter 6 - 808-P2 Installation Guide

    Bar failure due to a leaking end cap is NOT covered by warranty. Note that a kit with all the required Loctite products is available from Garnet. For further details on the Loctite products see Technical Service Bulletin #17 on our web site, www.garnetinstruments.com. Page 14...
  • Page 15 Top view 10.0” 5.0” 2.0” Side view End view 1.5” 3.0” 2.0” 2.0” Schedule 40 pipe 0.25” 4.0” Material is 1/4” thick. 5. Make up an anchor by cutting a 4” X 16” piece of 1/4” thick material. Bend each end down at 90 degrees (see the diagram), so the resulting flat piece is about 4”...
  • Page 16 At the lowest point in the air line insert a T fitting with approximately two feet of 1/4” airline hanging down to provide a drain for any water than may get into the system. If a T fitting is not feasible, put a fitting into the bottom of the display enclosure and route the 2 feet of 1/4”...
  • Page 17 To program the alarms and the SpillStop see the alarm programming section. Contact Garnet for information concerning the connection of the GREEN/YELLOW remote wire.
  • Page 18 AUTOMATIC ALARM WIRING DIAGRAM CONSTANT 12 VOLT POWER SOURCE OPTIONAL SYSTEM STATUS WARNING HORN – LAMP (USE OR LIGHT CLEARANCE TYPE LAMP) SHUTDOWN RELAY ALARM RESET SWITCH WHITE WIRE YELLOW WIRE PURPLE WIRE The system status lamp is used to 12 Vcd BLACK WIRE verify that power is present to...
  • Page 19: Chapter 7 - Setting Display Density

    CHAPTER 7 - SETTING DISPLAY DENSITY hen the gauge is calibrated with the correct offset, it is assumed that the density of the product is 0.90 (specific gravity is 90% of pure water). The amount that the float sinks into the product will vary somewhat with the density of the product, and hence the gauge reading will change slightly.
  • Page 20 Stainless Steel Truck Float Buoyancy Product Amount Level Correction (inches) Specific Float Error 1/3” 1/6” Gravity Sinks (Inches) Mode Mode (Inches) 0.60 2.92 0.97 0.65 2.69 0.75 0.70 2.50 0.56 0.75 2.33 0.39 0.80 2.19 0.24 0.85 2.06 0.11 0.90 1.94 0.00 0.95...
  • Page 21 0.90 which is the default. Continue to hold down the button. 4. Put a magnet next to the display face by the “G” in Garnet, with the hole in the magnet facing left and right, not up and down.
  • Page 22 6. If no further action is taken, the display will revert to normal operation after about 5 seconds with no change in the float programming. This is useful if you just want to check the current float programming. 7. To change the float programming, press and release the button before the 5 second time expires, otherwise start again at step 3.
  • Page 23: Chapter 8 - 808-P2 Programming Instructions

    The display must be showing “no L” in order to set the mode. 4. Hold the magnet next to the display face by the “G” in Garnet. 5. Within a couple of seconds, the display will show the software revision, for example 8.18.
  • Page 24 8. If the magnet is held in place the software revision number, which is useful for checking the generation of display will be shown again. Remove the magnet to resume normal operation. Removing the magnet at any time other than when “P1-X” is shown will result in no change to the mode.
  • Page 25 8. Make sure that the fibre from the sender bar is connected to the gauge display, and plug the programmer plug into the gauge display. Press the BAR button. The INCHES display should show some inch reading, if it shows “no L” or “bad L’ check the fibre connection and the bar mode (1/3 or 1/6 inch).
  • Page 26 6. Starting at the 0 inch value of volume calibration, use the 0 to 9, decimal, E, F, L, U, or BL buttons on the keypad to enter the calibration. Press the ENTER button to store the value in memory. When ENTER is pressed, the inches will go to the next value.
  • Page 27: Chapter 9 - Troubleshooting Guide

    CHAPTER 9 - TROUBLESHOOTING GUIDE here are only 4 serviceable components in the gauge: the float, the sender bar, the interconnecting fiber optic cable, and the display. If the float is sunk, the display will read the bottom tank reading all the time.
  • Page 28 4. If a programmer is not available, a quick test can be made of the bar by jumpering the two top pins on the programming plug in the display. This converts the display into reading raw inches only, the calibration is ignored.
  • Page 29 4. If only the alarms do not work then copy the calibration into the 817-USB to check if the points are programmed. If they are then connect a fiber from the 817-USB OPTICAL OUTPUT to the display optical connector. Connect the positive terminal of an ohm meter to the alarm wire, and the negative terminal of the ohm meter to the ground (green) wire.
  • Page 30: Chapter 10 - Specifications

    CHAPTER 10 - SPECIFICATIONS 810-X SENDER BAR Resolution 8 mm ( ”) Accuracy +/- 6 mm (+/- ”) Bar construction 316 stainless steel seamless tube Enclosure: PBT plastic, lid is polycarbonate Enclosure material PBT plastic Lid: polycarbonate Maximum tank height Tank height up to 221 cm (87”) Battery power Powered by a lithium battery with a lifetime of...
  • Page 31: Chapter 11 - Service & Warranty Information

    Alberta, T8A 4G7. Returned warranted items will be repaired or replaced at the discretion of Garnet Instruments. Any Garnet items under the Garnet Warranty Policy that are deemed irreparable by Garnet Instruments will be replaced at no charge or a credit will be issued for that item subject to the customer’s request.