Bus Data: BUS-D485
Its works through the RS-485 protocol, its connection is made using 4 wires, 2 for
power supply and 2 for data. The system is able to supervise each device connected
to the bus and generate a fault in the event of an error condition.
The maximum connection distance between the panel and the devices is 200
metres.
• Supports up to 8 keyboards.
• 3 EXP-8Z Expander modules.
• 1 Auxiliary Power Supply 1.5A FRA-200
• 1 Adapter cable for local programming (PC-Link).
Data Bus: BUS-C485
It is specially designed for high speed data transmission, it works through the
RS-485 protocol, its connection is made using 4 wires, 2 for power supply and 2 for
data.
The system is able to supervise each device connected to the bus and generate a
fault in the event of an error condition. The maximum connection distance between
the panel and the devices is 200 mts.
• Supports IP-500G, 3G-COM-G/4G-MAX-G devices.
Audible Alarm Output
The system supports up to 3 alarm outputs, using a combination between
Programmable Outputs (PGMs) and the Outdoor Siren Output.
Each programmable output can be configured as a siren output for any of the 2 par-
titions, so you could have 2 siren outputs (independent for each partition), and an
external siren output common to both partitions through the panel's Siren Output.
The siren sound is continuous or pulsating in the event of a fire alarm.
The fire alarm can be configured to be Pulse (1 second on, 1 second off) or Tempo-
rary 3, according to NFPA 72 standard (500mS on, 500 mS off, 500mS on, 500 mS
off, 500mS on, 500mS on, 1.5 sec. off).
• 1 1.4A, 12VDC Outdoor Siren output.
Monitored for short-circuit and disconnection.
• 2 Siren outputs per PGM.
NOTE: Take into account the current values when connecting a siren to a program-
mable output, as these are not supervised in the event of excess consumption.
Power requirements
Transformer: 16.5 VAC, 25VA.
Battery: 12 volt 4Ah minimum.
Regulated Energy Supply
2 independent power supply outputs: AUX and AUX-3G/IP
• Supply: AUX 700mA, 12 VDC
• Power supply: AUX-3G/IP 300mA, 12 VDC
EEPROM memory
No loss of programming or system status in the event of a complete power failure.
Garnet Keypads Specifications: KPD-800/KPD-860/KPD-860RF/ G-LED 732/
G-LCD732/G-LCD732RF.
• They are connected by 4 wires.
• Internal piezo buzzer with volume control.
• Backlight brightness control (only for models KPD-860/KPD-860RF/ G-LD732/
G-LCD732RF)
• Built-in radio frequency receiver (Model KPD-860RF/G-LCD732RF only).
• Anti-disassembly and anti-disassembly tamper.
• Independent indication of partition statuses.
• Separate armed, away and disarmed keys for facilitate their use.
Communication protocols
• Residential SMS (Only with 3G-COM-G/4G-MAX-G).
• SDC2 (Only with 3G-COM-G/4G-MAX-G or IP-500G).
• DC1 (Only with 3G-COM-G/4G-MAX-G or IP-500G).
System monitoring features
• CA power failure (on panel).
• CA power failure (on auxiliary source FRA-200).
• Low battery condition (on panel).
• Low battery condition (auxiliary source FRA-200).
• Failure of auxiliary power supply.
• Zone fault (supervised zones).
• Lack of internal clock programming.
• Siren output faults (disconnection and over current).
• Mobile Data communication failure (3G-COM-G/4G-MAX-G only).
• SMS communication failure (3G-COM-G/4G-MAX-G only).
• Link Failure (IP-500G and 3G-COM-G/4G-MAX-G only).
• Low battery per zone (only with wireless sensors).
• Zone Tamper (only with wireless sensors).
• Keyboard Tamper.
• Monitoring of modules installed in the BUS-D485 and BUS-C485.
• Failure in fire zones.
• False Alarm Prevention Features
• Audible Exit Delay with differentiated sound in the last 10 seconds.
• Audible input delay.
• Double-triggered alarm in zones.
• Cross Zone Burglary Alarm.
• Independent entry/exit times for each partition.
• Auto Arming and Auto Disarming with independent programmable times and
days for each partition.
• Auto arming on inactivity in zones with independent programmable times for
each partition.
• Keypad-activated manual communication test.
• Programmable automatic communication test with start time and intervals.
• All modules are connected to the system via a 4-wire bus. Up to 200m from the
PC-732G® panel.
• A 512-log event memory with date and time of occurrence. The memory can be
viewed with the KPD860 /860RF G-LCD732/ keypad. G-LCD732RF and/or with
AC4 Software.
• Automatic Shutdown: In the event of AC power failure and a significantly dischar-
ged battery, the panel will automatically shut down and restart when AC power
returns.
• Swinger Shutdown: Separate programmable counters for 17 types of shutdowns
different faults and/or alarms.
• Force arming for local and/or remote arming modes.
• Time programmable retransmission of Test Report and/or Network Fault Report
in the event of a communication failure.

1.2 Additional Devices

LCD Keyboard with Wireless Receiver KPD-860RF/G-LCD732RF
The Wireless Receiver is built into each keypad, and can be used to connect up to
24 wireless sensors, 64 remote controls, and 4 PGM-W/MA-220G to the system.
2-Way Wireles System® communication system.
All wireless sensors operate at 434 MHz and are bi-directional monitoring devices,
using CR123A lithium batteries.
NOTE: KPD-860RF/G-LCD732RF keypads shall be assigned addresses 1-4.
If a KPD-860RF/G-LCD732RF keypad is assigned an address greater than four, the
keypad will override its RF receiver.
The following devices are available:
• Wireless Motion Detector DGW-500. Adds wireless space protection to a sector of
the site
• Universal Wireless Transmitter DGM-300. Adds wireless door/window contacts to
your system
• PGM-W/MA-220G programmable wireless output module: It allows, without the
need for interconnection of cables, to control lights, motors, automatic irrigation
and many other devices.
• Wireless Remote Control TX-500
The 3 buttons on the remote control are configurable for different functions.
They are:
• Arm and disarm the system.
• Partition panic button.
• Activate a PGM output.
• Activate PGM-W./MA-220G output
• Wireless outdoor sensor IR-1000RF. Ideal for outdoor detection
• Wireless Photoelectric Smoke Detector DH360i. Early fire detection
3G-COM-G / 4G-MAX-G Cellular Communicator
The 3G-COM-G / 4G-MAX-G Cellular Communicator can be used in two different
forms:
• WiFi reporting as first means and cellular network as backup.
• Reporting by cellular network as first and only means.