T30 Sensors DC-Voltage Series
Quick Start Guide
Self-Contained, DC-Operated Sensors
For complete technical information about this product, including installation instructions, application requirements and guidelines, EU Declaration of
Conformity, technical specifications, and accessories, see
Models
Model 1
Sensing Mode
T306E
T30SN6R
T30SP6R
OPPOSED
T30SN6LP
P
T30SP6LP
POLAR RETRO
T30SN6FF200
T30SP6FF200
T30SN6FF400
T30SP6FF400
FIXED-FIELD
T30SN6FF600
T30SP6FF600
Wiring Diagrams
Cabled Emitters
3
–
10-30V dc
1
+
Quick Disconnect Emitters
1
+
10–30 V dc
3
−
4
not used
2
not used
1 Integral 2 m (6.5 ft) unterminated cable models are listed.
•
To order the 9 m (30 ft) PVC cable model, add the suffix "W/30" to the cabled model number. For example, T306E W/30.
•
To order the 4-pin M12/Euro-style integral quick disconnect model, add the suffix "Q" to the model number. For example, T306EQ.
•
Models with a quick disconnect require a mating cordset.
Original Document
116161 Rev. C
www.bannerengineering.com
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry
necessary to allow its use in personnel safety applications. A sensor failure or malfunction
can cause either an energized or de-energized sensor output condition.
Output
-
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN Standard
3
–
10-30V dc
1
+
4
Load
2
Load
NPN Alarm
1
–
10-30V dc
3
+
4
Load
2
Alarm
8 October 2018
and search 121524.
Range
60 m (196.8 ft)
6 m (19.7 ft)
200 mm (7.9 in) cutoff
400 mm (15.7 in) cutoff
600 mm (23.6 in) cutoff
PNP Standard
Key:
1
+
10-30V dc
3
–
4
Load
2
Load
PNP Alarm
3
+
10-30V dc
1
–
4
Load
2
Alarm
LED
Infrared, 950 nm
Visible red, 680 nm
Infrared, 880 nm
Wire 1 = Brown
Wire 2 = White
Wire 3 = Blue
Wire 4 = Black
116161