Specifications
®
VLT
AutomationDrive FC 302
High/normal overload
(High overload=150% current during 60 s,
normal overload=110% current during 60 s)
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload)
(at 575/690 V) [A]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 550 V) [A]
Continuous (at 575 V) [A]
Continuous (at 690 V) [A]
Maximum number and size of cables
per phase (E2h)
9
9
- Mains and motor without brake [mm
- Mains and motor with brake [mm
- Brake or regen [mm
Maximum number and size of cables
per phase (E4h)
- Mains and motor [mm
2
- Brake [mm
(AWG)]
- Load share or regen [mm
Maximum external mains fuses [A]
Estimated power loss at 600 V [W]
Estimated power loss at 690 V [W]
4)
Efficiency
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Power card overtemperature trip [°C (°F)]
Fan power card overtemperature trip [°C (°F)]
Active in-rush card overtemperature trip
[°C (°F)]
Table 9.4 Electrical Data for Enclosures E1h–E4h, Mains Supply 3x525–690 V AC
1) American Wire Gauge.
2) For fuse ratings, see chapter 9.7 Fuses.
3) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-
efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for
slots A and B each add only 4 W.
4) Measured using 5 m shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency
class, see chapter 9.4 Ambient Conditions. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
74
VLT® AutomationDrive FC 302
2
(AWG)]
1)
2
1)
(AWG)]
2
1)
(AWG)]
2
1)
(AWG)]
1)
2
(AWG)]
1)
2)
3), 4)
3), 4)
Danfoss A/S © 04/2018 All rights reserved.
N560
HO
NO
HO
450
500
500
600
650
650
560
630
630
E1h/E3h
596
630
659
894
693
989
570
630
630
855
693
945
568
600
628
568
627
627
681
753
753
574
607
635
549
607
607
549
607
607
6x240 (6x500 mcm)
6x240 (6x500 mcm)
5x240 (5x500 mcm)
5x240 (5x500 mcm)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
4x185 (4x350 mcm)
800
8069
9208
8543
7848
8921
8363
0.98
0–590
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
± 15% (tolerance relates to variety in voltage and cable conditions.) These
N630
N710
NO
HO
560
560
750
750
710
710
E2h/E4h
E2h/E4h
763
763
839
1145
730
730
803
1095
727
727
727
727
872
872
735
735
704
704
704
704
6x240 (6x500 mcm)
5x240 (5x500 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
1200
1200
10346
10319
10066
10060
0.98
0.98
0–590
0–590
110 (230)
110 (230)
80 (176)
80 (176)
85 (185)
85 (185)
85 (185)
85 (185)
85 (185)
85 (185)
NO
670
950
800
889
978
850
935
847
847
1016
857
819
819
12723
12321
MG38A202