sensor. When the lift arm is at the top, the sensor is blocked. Move the lift arm down
to unblock the sensor. Press the operator button to exit the test. Below is the bottom
view of the lift arm.
Lift Home Sensor
Media Plunger/Disc Present Sensor
07 – Gripper Media Diagnostic
This test is to check the Disk Present Sensor located inside the lift arm. The sensor is
blocked when the Media Plunger is pressed upward when a disc is gripped in the
Gripper Fingers. Run this test and push up on the Media Plunger and the panel
displays "Blocked".
Press the operator button to exit the test.
08 – Door Open Diagnostic
This test is to check the Door Open Sensor located at the rear of the supply bin area.
Run this test and close the door and the panel displays "Blocked". Open the door and
the panel displays "Unblocked".
Press the operator button to exit the test.
09 – Output Tray 1 Diagnostic
This test is to check the Tray Sensor (optical reflective sensor) in the Output Tray.
Tests 9 through 13 are selected for each tray sensor. Trays are numbered on the edge
Door Open Sensor
27
Gripper Fingers
Lift Arm
Supply Bin