04 – Jog Lift Diagnostic
Use this test to help align the printer and recorders.
PRESS/REL to JOG
HOLD to EXIT.
After pressing the operator button, the motor energy is released so the Leadscrew can
be rotated by hand to move the lift arm for finer movements. A disc can be placed in
the gripper fingers to check alignments. See
18.
Press and hold the operator button to exit this test.
Leadscrew
05 – Solenoid Test Diagnostic
This test powers on and off the Gripper Finger Solenoid, which moves the gripper
fingers.
Press the operator button to stop the test.
Gripper Finger Solenoid
06 – Lift Home Diagnostic
This test is used to check the Lift Home Sensor located inside the lift arm. The sensor
is blocked when the lift arm is at the top of the lift column. Once this test is selected,
the leadscrew can be rotated by hand to move the lift arm up and down to test the
"Printer
Alignment" directions on page
Lift Arm
Lift Arm
26
Recorder Drawer
Gripper Media Sensor