11.3 Auto Configuration File
To execute the auto configuration mode, it is required to create the auto configuration file, which is an
exclusive CFG file, in the USB memory in advance.
The auto configuration file is stored in the following path under the name of "AUTO CONFIG.CFG".
/ATA0/SYSTEM/AUTOCONFIG.CFG
11.3.1
Format
Auto configuration file has the following formats.
BA400T,0300
BA400T V1.0A
/ATA0/SYSTEM/BA400-BOOT2-Vx.x-xx.bin
/ATA0/SYSTEM/BA400-MAIN-Vx.x-xx.bin
/ATA0/SYSTEM/BA400-CG-Vx.x-xx.bin
11.3.2
Model Information
Applicable model's information is stored.
The information is comma separated. The first half is the model name (the above example indicates BA400T
Type 1 203-dpi model) and the second half is the PC board information.
If the actual printer and this model information do not match, the auto configuration mode will not start.
Description of the model information:
BA400T,0300
PC board information
Model BA400T BA400T-G/T
11.3.3
Display Message
A message displayed on the LCD while the printer is in the auto configuration mode.
Word-wrap feature is enabled.
Only characters that can be expressed with ASCII are allowed to be input.
11.3.4
Firmware File to be downloaded
Name of the file to be downloaded
Example
0300:PF MAIN Board
Model information
Display message
Firmware file to be downloaded
Firmware file to be downloaded
Firmware file to be downloaded
149