8.5.26
X ADJUST
Max.
Min. value
value
+99.9
-99.9
Notes:
1. The X ADJUST parameter can fine adjust the print position in X-coordinate (horizontal direction). The fine
adjustment shall be performed so that the print position falls within the effective print width. (The X
coordinate fine adjustment in the negative (-) direction is effective until the print field reaches coordinate 0.
The coordinate does not change any further even if the fine adjustment is continued in the negative
direction.)
2. The X-coordinate fine adjustment value is not applied to self-diagnosis results printing (maintenance
counter and parameter settings, and auto diagnosis).
8.5.27
X ADJ. METHOD
TYPE1 : Minus X adjustment will be ignore when X adjustment reached to "0" coordinate.
TYPE2 : Minus X adjustment will be available even though X adjustment reached to more
than 0 coordinate
Remarks: In the case of TYPE1, the field that reaches the coordinate 0 after fine adjustment in the
negative direction remains 0 even if the fine adjustment is made further in the negative
direction.
In the case of TYPE2, fine adjustment in the minus direction is possible even more than
coordinate 0. However, printing is halfway.
8.5.28

HEAT ENERGY TYPE

TRANS.(RIBBON)
DIRECT THERMAL
Remarks: The HEAT ENERGY TYPE parameter is intended to make the printer perform appropriate
printing for the supplies used (media such as label and tag, and ribbon). Use of a different supply
from the setting may cause poor printing.
Step
Display
0.1
Decimal
Integer
Decimal
Sign
digit
Exist
2
X Y Z
+
88
Unit of
0-padding
place
measure
1
None
mm