10. HYDRAULIC OIL TANK
1)
STRUCTURE
The oil from the hydraulic tank is sent from the pump through main control valve to the cylinders.
In the return circuit, the oil from various parts merges.
A part of oil is cooled in the oil cooler, passes through the hydraulic filter and returns to the
hydraulic tank.
1
Suction filter
2
Return filter
3
Suction flange
4
Return flange
5
Gasket
6
O-ring
7
Level gauge
9
16
10
14
11
8
14
4
5
18
19
17
1
6
3
13
8
Hydraulic oil cap
9
Air breather cap
10 Air breather filter
11 Rubber hose
12 Magnet plug
13 Bolt with washer
14 Clamp
6-25
7
19
2
15
12
15 O-ring
16 Hexagon bolt
17 O-ring
18 O-ring
19 Hexagon bolt