Led Display, Normal Operation; Led Display, Temperature Adjust Mode - Pace ST 45 Operation And Maintenance Manual

Soldering systems
Table of Contents

Advertisement

3. Press the Scroll Up (
step 4. If a Password has been previously programmed into the system, "EP0" will be appear
on the LED Display at this point. When this message appears, the operator must enter the
correct Password before adjusting the temperature.
4. Adjust the temperature by pressing and holding Scroll Up (
Observe the display as the Set Temperature increases first in increments of 1° and then in
increments of 10°. When the desired temperature is reached, release the key. NOTE: The
Set Temperature can only be within the set temperature limits. If the lower limit is reached,
the display will read off. If the upper limit has been reached, the display will read "HiL".
Temperature limits can be adjusted in the Set-Up Mode
5. Press the Program Key (
6. Observe the Digital Readout as the temperature reaches and stabilizes at the Set Tip
Temperature
7.
Manually force the system into Temperature Setback by pressing and holding the Scroll
Down (
) Key and the Scroll Up (

8. When the display begins to blink, the system is in Temperature Setback mode and will
reduce the set temperature to 177°C (350°F). NOTE: If Auto Off has been enabled in the
Set-Up Mode, the system will enter Auto Off (temperature Off and LED Display flashing "Off")
after the preset time of handpiece inactivity. Auto Off can be exited by pressing any key.
9. To exit Temperature Setback mode, perform any one of the following:
a) Press and release a Key (any of the 3 keys). This is the preferred method.
b) Wipe the hot handpiece tip on a wet sponge to lower the tip temperature.
c) Turn the Power Switch Off ("0") and then back on ("I").
10. The system is now in normal operation. Observe the LED Display as the tip temperature
reaches and stabilizes at the Set Temperature. Allow time for the temperature to stabilize at
the Set Temperature before using.
NOTE: Read the "Customize Your System" sections of this manual to utilize the full capabilities of
the system.

LED Display, Normal Operation

The LED Display provides a 3-digit display of temperature information. The LED Display will show:
1. A display of "888" on initial power up to ensure that all LEDs on the display are
working.
2. A display of the software version of the installed microprocessor (e.g., "1-2") for 2
seconds on initial power up after the "888" is displayed.
3. Actual tip temperature of the connected handpiece during normal operation.
4
The tip temperature displayed will flash when the system is in Temperature
Setback.
5. The displayed temperature will decrease and stabilize at 177°C (350°F) when the system is
in Temperature Setback.
6. "OFF" when the Set Tip Temperature has been set to Off (below minimum set tip
temperature). Refer to the "Set-Up Mode" portion of this manual.
7. "OFF" plus the LED Display will be flashing when the unit has entered Auto Off.
Refer to the "Set-Up Mode" portion of this manual.
8
Error messages ("OSE", "SSE" or "OCE") if a system fault is detected. Refer to the
"Corrective Maintenance" portion of this manual.

LED Display, Temperature Adjust Mode

The LED Display will show the following when adjusting the desired Set Tip Temperature.
1. The Set Tip Temperature.
©2001 PACE Inc., Laurel, Maryland
All Rights Reserved
) Key. The Set Temperature is now displayed, immediately perform

) and the system will return to normal operation.
) Key.

) Key or Scroll Down (

Page 12 of 20
) key.


Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St 55St 45eSt 55e

Table of Contents