Led Operation; Operation; Accessing Programming Menu; Password Menu - Pace MBT 301 Operation And Maintenance Manual

Digital soldering/desoldering system
Table of Contents

Advertisement

LED Operation

The Green colored Temperature LED on the power source front panel indicates System Status.
LED Green - Indicates that the set tip temperature has been reached. Power to the handpiece is
cycling Off and On to maintain set temperature.
LED Amber - Continuous power is being delivered to the handpiece. This condition is evident
when the system is first powered up (handpiece heater cold) or the Variable Temperature Control
setting is increased.
LED Red - No power is being delivered to the handpiece heater. If the LED never illuminates,
check for a faulty handpiece heater (see Corrective Maintenance section).

Operation

Accessing Programming Menu

The menu driven LED Display of the MBT 301 system allows you to easily customize your system. By
accessing the programming menu, you can:
• Enter, remove or change a Password.
• Set the Default Temperature scale to °F or °C as desired.
• Change the Upper and Lower Temperature limits.
• Enable or disable the Temperature Setback feature.
• Enable or disable the Auto Off feature.
• Enable or disable the Scan feature.
• Change the Default Calibration Offset Option
• Calibration Option 2 LED reset capability
• Enable or disable the display contrast and backlight settings.
To access set up mode, press and hold the PROGRAM Key
when "Software Version" appears. Pressing the PROGRAM Key
option without changing the stored setting.
Follow the MBT 301's on screen prompts to review or set each menu option starting with the
password feature.

1. Password Menu

Same
Retains previous password and move to the next step.
Yes
Prompts the operator to enter a new password. Use the scroll up / down keys on the
system front panel to select a four digit password. Once password is entered, press the
PROGRAM Key
a password will disable the password feature.
No
Selecting "NO" bypasses the password feature and moves to the next step.

2. Setting Temperature C /F

The LED Display now shows the stored default Temperature Scale °C or °F temperature shown on
LED Display). Choose one of the following:
a) Press the PROGRAM Key to keep the stored default Temperature Scale.
b) Press and release the
Press and release the PROGRAM Key to move to the next step.
©2013 PACE Worldwide, Southern Pines, North Carolina All Rights Reserved
 
to accept the password and move to the next step. Entering "0000" as
UP Key to change the default Temperature Scale.
while powering on unit. Release key
will scroll through each menu
Page 13 of 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents