c) Press and release the Scroll Down (
Temperature Limit. Press and release the Program Key to proceed to the next
step.
10. The LED Display now shows the stored default Low ("Lo") Temperature Limit with the
display alternating to show "Lo" and the stored limit. Choose one of the following:
a) Press and release the Program Key (
Limit (204°C, 400°F).
b) Press and release the Scroll Up (
Limit. Press and release the Program Key to proceed to the next step.
c) Press and release the Scroll Down (
Temperature Limit. Press and release the Program Key to proceed to the next
step.

Offset Constant

11. The LED Display now shows the stored Offset Constant with the display alternating to
show "OF" and the stored Offset Constant. Choose one of the following:
a) Press and release the Program Key (
Constant.
b) Press and release the Scroll Up (
An Offset Constant of 0-133°C (0-240°F) can be stored. Press and release the
Program Key to proceed to the next step.
c) Press and release the Scroll Down (
Constant. Press and release the Program Key to proceed to the next step.
NOTE: If the attached handpiece is disconnected when the system is powered up, any stored
Offset Constant is reset to zero. The Offset Constant must be entered again in the Set-Up Mode.

Temperature Setback

12. The LED Display now shows the stored Temperature Setback time as "S-X" (x=0 thru 9).
Time is shown as tens of minutes (e.g., "S-3" equals 30 minutes). A display of "S- 0"
indicates that Setback is disabled. Choose one of the following:
a) Press and release the Program Key (
Temperature Setback time.
b) Press and release the Scroll Up (
Temperature Setback time. Press and release the Program Key to proceed to the
next step.
d) Press and release the Scroll Down (
Temperature Setback time. Press and release the Program Key to proceed to the
next step.

Auto Off

13. The LED Display now shows the stored Auto Off time as "AOx" (x=0 thru 9).
Time is shown as tens of minutes (e.g., "AO3" equals 30 minutes). A
display of "AO0" indicates that Auto Off is disabled. Choose one of the
following:
a) Press and release the Program Key (
time.
b) Press and release the Scroll Up (
Press and release the Program Key to proceed to the next step.
e) Press and release the Scroll Down (
Auto Off time. Press and release the Program Key to proceed to the next step.
Temperature Display Impedance
©2001 PACE Inc., Laurel, Maryland
All Rights Reserved
) Key to decrease the stored High

) to keep the stored Low Temperature
) Key to increase the stored Low Temperature

) Key to decrease the stored Low

) to keep the currently stored Offset
) Key to increase the stored Offset Constant.

) Key to decrease the stored Offset

) to keep the currently stored
) Key to enable and/or increase the stored

) Key to decrease or disable the stored

) to keep the currently stored Auto Off
) Key to enable and/or increase the Auto Off.

) Key to decrease or disable the stored