Delta CS-H9-70HG User Manual page 87

Ip camera tester
Table of Contents

Advertisement

measure range)
F. Continuity Testing
WARNING!
When testing the circuit continuity, be sure that the power of the circuit has been shut down and all
capacitors have been discharged fully.
a. Connect the black test lead to the "COM" jack and the red test lead to the "V/
b. Select
, enter the continuity test, Connect test leads across two point
of the circuit under testing.
c. If continuity exists (i.e., resistance less than about 50Ω), built-in buzzer
will sound.
G. Diode Testing
WARNING!
The capacitance of a capacitor should be tested separately, should not test in the installation
of circuit.
a. Connect the black test lead to the "COM" jack and the red test lead to
Ω
the "V/
" jack. (the red lead anode "+" )
b. Select
, enter the diode testing.
c. Connect test red lead across to the anode, the black lead to the
cathode of the diode under testing.
000.0Ω
→ 660Ω range
0.000 KΩ → 6.600KΩ range
00.00 KΩ → 66.00KΩ range
000.0 KΩ → 660.0KΩ range
0.000 MΩ → 6.600MΩ range
00.00 MΩ → 66.00MΩ range