Delta CS-H9-70HG User Manual page 78

Ip camera tester
Table of Contents

Advertisement

User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click
"Cable", "Type" to select user-defined 1 for calibration, 11 groups user-defined can be set.
1. Select user-defined and click "Calibration" to enter test, click "user-defined 1" can define cable name,
such as: AiPu BNC-5
2. Click "Cable", "Type" to select cable, and corresponding type, for example, if testing BNC cable,
select "BNC", if testing communication cable 75-2, select SYV 75-2.
3. Click "+" or "-" to adjust wave speed, while display length is the same with the actual Length, click
"Save" to save calibration data. It can be used for the same cable testing next time.
Page.73.