  • Page 1 IP camera tester User Manual (V01.00)...
  • Page 2 Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera tester and use properly. For using the IP camera tester safely, please first read the「Safety Information」carefully in the manual. The manual should be kept well in case of reference. Keep the S/N label for after-sale service within warranty period.
  • Page 3: Table Of Contents

    Content 1. Safety information ..........................1 2. IP Camera Tester Introduction ......................2 2.1 General ............................. 2 2.2 Packing list ..........................2 2.3 Function interface ........................3 3. Operation ............................8 3.1 Installing the Battery ......................... 8 3.2 Instrument connection ....................... 9 3.2.1 IP camera connection .....................
  • Page 4 3.3.13 Auto HD ( *Optional )....................44 3.3.14 HD Coaxial & Analog level test (* Optional ) .............44 3.3.15 SDI Camera Test (* Optional ) ..................47 3.3.16 CVI camera test (* Optional ) ..................47 3.3.17 TVI camera test (* Optional ) ..................54 3.3.18 AHD camera test (* Optional ) ..................56 3.3.19 NET TOOL PRO ......................57 (1)IP address scan ......................57...
  • Page 5 3.3.35 Data monitor .......................98 3.3.36 Audio player ........................99 3.3.37 Media Player .......................99 3.3.38 RTSP Player ......................100 3.3.39 Hik test tool .......................101 3.3.40 Dahua test tool......................105 3.3.41 Update ........................110 3.3.42 Office ........................111 3.3.43 LED Flashlight ......................112 3.3.44 Browser ........................112 3.3.45 Notepad ........................113 3.3.46 Professional WIFI Analyzer ..................114 3.3.47 System Setting ......................115 3.3.48 File explorer ......................119...
  • Page 6: Safety Information

    1. Safety information ◆ The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc. ◆...
  • Page 7: Ip Camera Tester Introduction

    ◆Never perform capacitance measurements unless the capacitor to be measured has been discharged fully. ◆Never measure any of resistance, capacitance, diode or continuity measurements on live circuits. Visual laser sources When you turn on visual laser sources, please don't stare at it, or will damage to eyes When not using it, please turn it off and cover the protective cap.
  • Page 8: Function Interface

    2). Adaptor DC12V 2A 3). Network cable tester 4). Polymer lithium ion battery (7.6V DC 7800mAh) 5). BNC cable 6). RS485 cable 7). SC, ST connector(Only for optical power meter) 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models) 9).
  • Page 9 Press more than 2 seconds, turn on or off the device, short press to turn on or off the menu display The charge indicator: it lights red while the battery is being charged. As the charging is complete, the indicator turns off automatically The RS485 data transmission indicator: it lights red while the data is being transmitted The RS485 data received indicator: it lights red while the data is being received...
  • Page 10 Zoom- zoom out the image IRIS- close or decrease the aperture Focus- Focus the image nearby Upward, set function or add parameter. Tilt the PTZ upward Confirm key Rightward, select the parameter whose value will be changed. Add the value of the parameter.
  • Page 11 Top interface Bottom interface Cut-off button, when the instrument system is abnormal, press it to make the instrument power off immediately. After restarting the instrument with the power key, it can be restored to normal use. PSE power supply input interface/Lan test interface PoE power supply output/Lan test interface HDMI IN.
  • Page 12 Laser distance meter Visible red laser source emits Interface(Optional) Optical power meter interface (Optional) Video image /AHD/TVI/CVI signal input(BNC interface)/AHD/TVI/CVI(Optional). SDI input (BNC interface) (Optional). Video image signal output(BNC interface)/cable tracer interface. LED lamp Flash DC 12V 2A charging interface. DC 24V 2A output USB 5V 2A power output ,transmit data RS485 Interface: RS485communication for the PTZ.
  • Page 13: Operation

    3. Operation 3.1 Installing the Battery The tester has built-in lithium ion polymer rechargeable battery. The battery cable inside battery cabin should be disconnected for safety during transportation! Prior to the use of the instrument, the battery cables inside the battery cabin should be well connected.
  • Page 14: Instrument Connection

    3.2 Instrument connection 3.2.1 IP camera connection Power an IP camera with an independent power supply, then connect the IP camera to the IPC tester's LAN port, if the link indicator of the tester's LAN port is green and the data indicator flickers, it means the IP camera and the IPC tester are communicating.
  • Page 15: Analog Camera Connection

    3.2.2 Analog camera connection 1) Connect the camera's video output to the IP tester's VIDEO IN. The image will display on the tester after pushing the PTZ icon. 2) CCTV IP Tester "VIDEO OUT" interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor.
  • Page 16: Hdmi In

    1) Connect the SDI camera's video output to the IP tester's "SDI IN" interface, the image will display on the tester. The tester only come with SDI input interface. There is no SDI output interface. 2) Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface. 3.2.4 HDMI IN DVR or other device's HDMI out port connect to tester's HDMI in port, the meter will display input image.
  • Page 17: Hdmi Output

    3.2.5 HDMI output The built in HDMI output port can output live video from an analog or IP camera, recorded files, media files and images to HDTV monitors. Connect an HDMI cable from the IP tester to an HDTV monitor at any time.
  • Page 18: Short-Cut Menu

    IP Setting: Enter IP Settings interface. LAN INFO: Display network port or WIFI connection real-time upload and download speeds and other network parameters. TOUCH POINT: Display contact point place. NETWORK SPEED: Turn on WLAN net and displays current WLAN status. POWER OFF: Turn off the meter.
  • Page 19: Screen Capture

    You can long press any app in the all applications list, it will auto move to shortcut menu. If delete any app in the shortcut menu, please select a app and press several seconds, it will be deleted. 3.3.3 Screen capture Long press the key "enter”, can capture screen interface and save it in any time.
  • Page 20 When using a four-core cable to connect to a Gigabit device, would prompt "the link limited". Advanced link monitor It is for monitoring CVBS loop, Ethernet statistics, error frame statistics, frame length etc Page.15.
  • Page 21: Testerplay

    3.3.5 TesterPlay Mobile phone projection (only supports phones with Android system) When using local projection, the meter creates a WIFI hotspot, the phone connects to the meter hotspot, or the meter and the phone connect to the same WIFI network. When using Internet projection, the meter and phone is connected to the Internet.
  • Page 22: Ip Discovery

    After the voice intercom is turned on, the resonance between the mobile phone and the Tester can be improved by adjusting the distance between the devices or turning down the volume. Install the VLC player on the PC, open the VLC player "Media - Open Network Streaming", enter the RTSP address above the meter's QR code, and click "Play"...
  • Page 23: Ipc Test Pro

    Local IP: Tester's IP address, Tester can auto-modify the tester's IP to the same network segment with the scanned camera's IP Discovery IP: Connected tester equipment's IP address. If the camera connected to the tester directly, tester will display the camera's IP address, if tester connects to Local Area Network, it displays the current IP address.
  • Page 24: Rapid Onvif

    Application: Support multi-segment IP address scan, can visual display camera manufacturer, click IP address to play the image. Connect IP camera, can supply the power to PoE camera. Real-time display network port connection status. By one key to connect camera test tool, browser can login and configure camera. Batch activate Hikvision and Dahua cameras.
  • Page 25 If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List. Tester can auto login camera and display camera image. Click the button “Refresh”, tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the “Device List”.
  • Page 26 Cross network scan: After open this function , enter “Setting”-“IP Settings”-“Advanced”to add other network segments IP, Rapid ONVIF function can across network segments to scan camera’s IP. Auto Login: After open this function, tester can auto login camera and display camera image (The login password is the same with last time, the first time using password is the default password "admin") Video transmission protocol: UTP and TCP protocol...
  • Page 27 IP camera video settings: Click “Video Set” to enter the IP camera’ s encoder and resolution settings. Make the desired changes and click“OK” to save. Image setting: Click“Imaging Set”to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. Page.22.
  • Page 28 Profiles:Click “profiles",can view video streaming current configuration files, as well as switch between Major stream and minor stream . Preview pictures:Quickly preview and zoom in or out pictures, automatically and manual refresh Identification: click “Identification”to view information of the camera Page.23.
  • Page 29 Time set: click“Time set”, Select " Manual set" to set up the time of camera Page.24.
  • Page 30 Maintenance: For camera software reset or restore to factory settings. Network setting: Click “Network Set” to change the IP address. Some cameras cannot support change IP address, so there is no change after saving. Page.25.
  • Page 31 User Set: Modify camera user name, password etc. parameters Zoom in image: Press the key to enter the zoom mode. Press it again to exit zoom mode. When the image is enlarged tap left, right, up or down on the image to move the whole image on the screen When the image is enlarged, if not operate on touch screen, it can operate by the keyboard, press the key "ZOOM+"...
  • Page 32 If it is network video input to the tester, as the tester supports resolution up to 1080p, the input image will be very clear after it is enlarged. This is greatly helpful for the installers to ensure the IP camera’s video coverage and decide the IP camera’s install site.
  • Page 33 To rename or delete a photo, click and hold on the file until this screen appears: Video files can play in the Video player on the main menu. Modify channel name: clicking "OSD" will pop up OSD settings, including time, channel name and other optional items.
  • Page 34 Set preset position: Move the camera to preset position, enter the preset number on the Bottom right corner to complete position preset. Call the preset position : Select the preset number on the left, click "Call" to call preset Page.29.
  • Page 35 PTZ Speed set: Horizontal and Vertical Speed set RTSP: Get RTSP address of the current camera Doc: Auto generate test reports document of camera, click "generate document” . Click Preview to view the report document Page.30.
  • Page 36 Enter the camera test information, click "Create Document" to complete the report. Click doc menu again, you can preview the report document. Icons description: the description of function icons on the bottom toolbar Page.31.
  • Page 37: Non Onvif

    3.3.9 NON ONVIF Display image from the 4K H.265 camera by mainstream Click icon to enter IP camera test Note: Currently, the IPC Test App only supports some brands' specific IP cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more. If the camera is not fully integrated, please use the ONVIF or RTSP apps.
  • Page 38 Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera's RTSP have not been start or without, it will tip "auto match fail, please switch to manually selecting". IP Camera's IP: Enter the IP camera's IP address manually or click "Search" to auto-scan for the IP camera's IP address.
  • Page 39: Hdmi In

    IPC User Name: Enter IP camera's user name. IPC Password: Enter IP camera's login password. IPC Port: When you select the IP camera type, it will default the camera's port number and doesn't need to be changed. After all settings are completed, click "Enter" to view the live video. If IP address setting has error or IP camera is not connected..
  • Page 40 (1) Snapshot Click the icon "Snapshot", when the video in, to take a picture and save the current video frame in the SD card as JPEG file. If the unit is set to the manual mode an "Input Name" pop up box will appear and you can enter a title for the snapshot.
  • Page 41 (2) Video record When you click the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Record" icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter or digit) to store in TF card, tester will hereby store the files in TF card after recording.
  • Page 42: Analog Camera Test

    Click to close and return to PTZ controller. (4) Recorded video playback Click the "Playback" icon to view your recorded videos. Tap on the video file image you want to watch. To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu "Video Player".
  • Page 43 A. Protocol Use the up and down arrow keys to move the yellow cursor to the "protocol", set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco-D, Samsung, Yaan, LiLin, CSR600, Panasonic, Sony-EVI etc. B. Port Click and move to "port" Select the communication port for the PTZ camera controlling (RS485) C.
  • Page 44 Check and set the protocols, address, interface and baud, all must be consistent with the dome camera, then the IPC tester can test. After setting the parameter, the tester can control the PTZ and lens To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction.
  • Page 45 3) 4 x zoom image display and Video out When image input, press to enter "zoom", press it again to quit. Using the touch screen to control PTZ camera movement: Tap left, right, upward or downward on the video image to move the PTZ camera in a desired direction. Stretch two fingers outward or inward on the touch screen to zoom the image in or out.
  • Page 46 5) Video record When you click the "Record" icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the "Record" icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins, appears dialog box "Input Name", user-defined the files name(by Chinese character, English letter, or digit) to store in SD card, tester will hereby store the files in SD card after recording.
  • Page 47 (6) Photo Click the icon "photo" to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears. Click to close and return to PTZ controller.
  • Page 48: Color-Bar Generator (Tv Out)

    Video files also can play in the main menu "Video Player". Image loop test: Test video optical transmitter and receiver and video cable, connect one end to the tester "VIDEO OUT" port, and the other end connected to "VIDEO IN" port, the signal send via "VIDEO OUT"...
  • Page 49: Auto Hd ( *Optional )

    judge if transmission has loss or interference. B. The tester sends out the pure color bar (such as white and black color), to test the monitor whether has bright or black dots C. The tester sends out video signal image to test if the image received by the monitor has excursion. 3.3.13 Auto HD ( *Optional ) Auto-recognize the resolution and Auto-display the image of the connected camera.
  • Page 50 Image display: Select the camera type, no need to select the resolution, click the camera icon, can browse the camera image directly. Level Meter Test: Need to select the camera type and resolution, click "test" to test the level Color bar generation: Click "CVBS", quickly enter color bar generation app Test Result:The percentage and signal grid of the level value.
  • Page 51 Page.46.
  • Page 52: Sdi Camera Test (* Optional )

    3.3.15 SDI Camera Test (* Optional ) SDI camera test, Dome camera test and PTZ control, click icon to enter. When tester receives SDI camera image, it will display the image data. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280x720P 25Hz, 1280x720P 30Hz, 1280x720P 50Hz, 1280x720P 60Hz, 1920x1080P 25Hz 1920x1080P 30Hz, 1920x1080I 50Hz, 1920x1080I 60Hz, EX-SDI: 2560x1440P /25/30FPS,...
  • Page 53 The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P 30FPS / 1280x720P 50FPS / 1280x720P 60FPS / 1920x1080P 25FPS / 1920x1080P 30FPS/2560x1440P 25FPS/2560x1440P 30FPS/ 2592x1944P 20FPS / 2960x1920P 20FPS / 3840 x 2160P 12.5/15 FPS (1)PTZ control 1.1 Coaxial PTZ control Click the icon "PTZ"...
  • Page 54 Enter PTZ address to perform parameters setting Operation instructions, please refer to "3.3.1 PTZ (1) Video monitor test" The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test. After setting the parameter, the tester can control the PTZ and lens. To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly.
  • Page 55 To control PTZ by key buttons ◆ Press arrow keys to control to control the PTZ direction of rotation ◆ Press the key to switch on or turn off the aperture. ◆ Press the key to adjust the focus manually. ◆...
  • Page 56 1.2 RS485 control Operation instructions, please refer to "3.3.1 PTZ (1) PTZ control parameters setting". (2)Coaxial camera menu setting Tap icon "UTC", select "menu setting" to enter the dome camera menu. Page.51.
  • Page 57 Input calling dome camera menu address code, after finishing the parameter settings, you can press the or click the icon to call the dome camera menu. Press arrow keys to set Page.52.
  • Page 58 (3) Snapshot, record, photo viewer and video play back, please refer to "3.3.1 PTZ (1) Video monitor test". Tap "close menu" or press the key " " to close camera menu. (4) Save setting Click icon "Set" on the right toolbar to enter storage setting. Support auto-storage and manual storage.
  • Page 59: Tvi Camera Test (* Optional )

    3.3.17 TVI camera test (* Optional ) HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P30FPS / 1280x720P 50FPS / 1280x720P 60FPS 1920x1080P 25FPS / 1920x1080P 30FPS / 1920x1080P 50FPS / 1920x1080P 60FPS //2048x1536P 18FPS/2048x1536P 25FPS/2048x1536P 30FPS /2560x1440P 15FPS/2560x1440P 25 FPS/2560x1440P 30FPS/2688x1520P 15FPS/2592x1944P 12.5FPS/2592x1944P 20FPS/3840 x 2160P 12.5/15 FPS Page.54.
  • Page 60 Coaxial camera menu settings Tap icon "UTC", select "menu setting" to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the or click the icon to call the dome camera menu. More operation instructions (such as PTZ control, coaxial camera menu setting, snapshot, recording and playback etc.), please refer to "3.3.6 CVI camera test".
  • Page 61: Ahd Camera Test (* Optional )

    3.3.18 AHD camera test (* Optional ) AHD camera, AHD dome camera test and PTZ control, Click icon to enter The tester supports resolution as follows: 1280x720P 25,30FPS / 1920x1080P 25FPS / 1920x1080P 30FPS/2048x1536P 18,25FPS/2048x1536P 30FPS /2560x1440P 15 FPS/2560x1440P 25,30 FPS/2592x1944P 12.5,20FPS/3840 x 2160P 15FPS (1) Coaxial PTZ control UTC control: select "PTZ control or PTZ control-2"(AHD camera has two different order, if select "PTZ"...
  • Page 62: Net Tool Pro

    3.3.19 NET TOOL PRO NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. (1)IP address scan Connect the cable to the LAN port. Set your IP address search range by changing the Start and End IP addresses.
  • Page 63: 2)Ping Test

    (2)PING Test PING is the most conventional network debugging tool, it is used for testing if the connected IP camera or other network equipment's Ethernet port is working normally and the IP address is correct. Connect a network cable to the LAN port and click the icon to open the PING tool.
  • Page 64 When test, need a tester or a computer installed Network Test Software as the Server, the other tester sends packet test. The two testers must be in the same network segment. a). Start the server: Click "Start Server" button to use the tester as a Server. It will display its IP address at the top of the screen.
  • Page 65 Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If use computer as the server, the computer IP address is :192.168.0.39 Tester as Client, tester's IP address is:192.168.0.238.
  • Page 66: 4)Port Flashing

    Or use tester as a Server, computer as test Client(select Client, input tester's IP address to test) When use tester as Server, shows results: (4)Port Flashing Connect a network cable to the meter's "LAN" port, click the icon to open the Port Flashing app. Click "Start".
  • Page 67: 5)Dhcp Server

    Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection.
  • Page 68: 6)Trace Route

    (6)Trace route It is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Please use professional Ethernet tester. Click to enter trace route Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally default is 30 Click "start"...
  • Page 69: Poe Power / Dc12V 3A And Dc 5V 2A Usb Power Output

    Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.20 PoE power / DC12V 3A and DC 5V 2A USB power output When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned on.
  • Page 70: Dc 24V 2A Power Output

    Note: 1. Don't input power into the "DC12/3A OUTPUT" port. 2. Don't output this DC12V/3A power to the DC12V/IN port of the IP camera tester to avoid destroy 3. The IPC tester power output is close to 3A, if the IP camera's power is over 3A, the tester will auto enter protection mode.
  • Page 71: Cable Test

    the camera. Notice: a. Don't input any power into the "DC24V/2A OUTPUT" port of the tester to avoid destroy. Man-made damage is not within our company's warranty b. Don't output this DC24V/2A power to DC12V/ IN port to avoid destroy. otherwise the tester will damage, and man-made damage is not within our company's warranty.
  • Page 72: Rj45 Cable Tdr Test

    If need several different number other types cable testers, should pay the additional cost. Cable test Tap "cable test sketch map", pop up Straight-through cable and crossover cable sketch, It is for line sequence reference, when the crystal on the first pressure in the twisted-pair. 3.3.23 RJ45 cable TDR test Connect cable to tester's LAN port, click icon "...
  • Page 73 Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display "online", if not link up or open circuit, screen display "open circuit", if cable pair is short circuit, screen display "short circuit". Length: The max test length is 180 meters, when cable is open circuit or short circuit, can test the cable length, if screen display "online", the testing result would be not accurate.
  • Page 74 Click "Help" to check the instruction of all parameters. Page.69.
  • Page 75: Cable Tracer

    3.3.24 Cable Tracer Connect tested cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. UTP mode is used for searching the normal network cable or other cables. STP mode is used for searching the shielded network cable.
  • Page 76: Tdr Cable Test (* Optional )

    maintenance and network engineering. While searching BNC cable, connect one port of the alligator clips to the copper core or copper net of the BNC cable, the other one to connect the earth wire (barred windows). Note: The battery of the cable tracer must according to corresponding positive pole + and negative pole -, otherwise will damage the tester.
  • Page 77 Inflection point: The position of break point or short-circuit of the cable, is where curve suddenly rises or falls after the smooth curve. Short circuit: The curve shows an upward trend after the inflection point Open (break point): The curve shows a downward trend after the inflection point 2) Curve operation Zoom: Zoom the curve.
  • Page 78 User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click "Cable", "Type" to select user-defined 1 for calibration, 11 groups user-defined can be set. 1. Select user-defined and click "Calibration" to enter test, click "user-defined 1" can define cable name, such as: AiPu BNC-5 2.
  • Page 79: Bnc Attenuation Test (* Optional )

    Application: TDR test is the use of pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen. TDR can test cable open circuit and short circuit, help engineer quickly find the cable's problem location.
  • Page 80 2. After calibration, the red clip clips the copper core of the BNC cable, and the black clip clips the outer envelope of the BNC cable. attenuation value will be displayed after connection, as below: 3. Click "Reset", the application will restore factory defaults. Page.75.
  • Page 81: Poe Voltage Test

    3.3.27 PoE Voltage test Click icon to enter PoE voltage measurement Connect a network cable from a PoE switch to the IP tester's PSE IN port. Connect an IP camera or other PoE using node to IP tester's LAN port, the PoE voltage and the cable's pin connection status show on the screen.
  • Page 82: Power Input Test

    3.3.28 12V power input test Connect 12V power adaptor to tester's charging port, then click icon "PoE" to enter voltage measurement app, screen show the current adaptor input voltage and power. Note: the current 12V input measured power is the battery charging power and the device working power, the measured power will change depending on the different of battery power and backlight brightness.
  • Page 83 1) SYMBOLS: U: DC Voltage Measuring A: DC Current Measuring Ω: Resistance Measuring : Diode Testing : AC Voltage Measuring : AC Current Measuring : Continuity Testing : Capacitance Measuring AC/DC Voltage and current measurement state display Auto- range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative...
  • Page 84 Manual range: 0.000V → 6.600V range 00.00V → 66.00V range 000.0V → 660.0V range 000.0mV → 660.0mV rang B. AC Voltage Measuring WARNING! You can't input the voltage which more than 660V AC, it's possible to show higher voltage, but it's may destroy the inner circuit.
  • Page 85 range. c.Manual range: 0.000mA → 6.6mA range 00.00mA → 66.00mA range 000.0mA → 660.0mA range → 10.00A range(use 10A socket) 00.00A d. Select the range to enter current measurement NOTE: ◆ When only the figure "OL" is displayed, it indicates over range situation and the higher range has to be selected.
  • Page 86 b. Select , enter the AC current measurement, manually select the range. c. Manual range: 0.000mA → 6.600mA range 00.00mA → 66.00mA range 000.0mA → 660.0mA range → 10.00A range(use 10A socket) 00.00A Note: ◆ When only the figure "OL" is displayed, it indicates over range situation and the higher range has to be selected.
  • Page 87 measure range) 000.0Ω → 660Ω range 0.000 KΩ → 6.600KΩ range 00.00 KΩ → 66.00KΩ range 000.0 KΩ → 660.0KΩ range 0.000 MΩ → 6.600MΩ range 00.00 MΩ → 66.00MΩ range F. Continuity Testing WARNING! When testing the circuit continuity, be sure that the power of the circuit has been shut down and all capacitors have been discharged fully.
  • Page 88 d. Connect test red lead across to the cathode, the black lead to the anode of the diode under testing. e. Tested diode, forward voltage low 30m, there is sound indication, then can finish the testing quickly without view the screen. H.
  • Page 89 While testing the capacitance of a capacitor to 660uF, the Max time will be 6.6 seconds, if the cap acitor is leaked or damaged, the data can't be read. The tester will be normal after disconnecting the capacitor. Manual range and Auto range When testing, click "Range select"...
  • Page 90: Optical Power Meter (* Optional)

    If input voltage over 600V, will damage the meter. ➢ mA current fuse range: 250V 1A if the current over the rated range ,fuse will melt to protect the meter .Pls use the same model when change the fuse, Pls opens the battery cover to change. Note: 10A socket without fuse protection, if over the current range Wrong using the 10A socket to measure the voltage, will damage the meter.
  • Page 91 Relative power value (optical link loss) measurement While testing, set the wavelength for measurement. Click "relative"(difference) to test, the tester Auto save current fiber power value as the base reference value. Input another optical fiber to be measured, the displayed new measurement and relative value is red color. Press it again to quit. Data hold and Relative measuring use together, the data is yellow while the function is effect.
  • Page 92: Visual Fault Locator (* Optional)

    3.3.31 Visual Fault Locator (* Optional) Click icon to enter VFL four status can select——"Steady mode", "Evasive 1Hz","Evasive 2Hz"and "Time off". Click button "Steady mode" to enter steady status, click button "Evasive 1Hz" and "Evasive 2Hz", to enter pulse mode, click button "Time off ", VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins).
  • Page 93: Infrared Measurement

    3.3.32 Infrared measurement When measuring, the bottom of the tester should be kept level with the edge to be measured, and click the "Measurement of wiring length" function icon to turn on the distance measurement function. Start: Click the "Start" button. When the button changes to "Measure", the red laser of the device is always on, which is used to aim at the distance measurement position.
  • Page 94 Measurement mode Length measurement mode: Measure the length of object Area measurement mode: Measure the length and width of the object separately. The two sides to be measured must be mutually perpendicular, If not perpendicular, the area calculation result will be inaccurate.
  • Page 95 the meter length (shown as below image 1) , if select rear reference, the measurement value includes the meter(shown as below image 2). Benchmark switch: Click “Benchmark switch”, can select front or rear reference mode. Image 1 Image 2 Note: If select the front reference mode, switch the cross coordinates to icons, the upper reference surface of the tester should be flush with the starting point of the object to be tested.
  • Page 96 Accumulation: Select the datas, the datas can be accumulated. Cumulative results are displayed at the b ottom. Testing record When each measurement completed, the testing record will be created according to measurement time. Click the empty place in Notes to edit the note, click delete icon to delete the testing record. Clear record: clear the testing record of current measurement mode Setting: Select measure unit, meter/foot/inch is optional Export data: Select the record, click “Export data”, will create a CSV file, the file records current...
  • Page 97 CVS management: The saved CSV file can be preview or delete. Safety precautions in operation: --- Do not point the laser beam at people or animals, and do not look directly at the laser beam. The instrument projects a Class 2 lasers according to IEC 60825-1 (635nm,<1mW), normal use is not harmful, but direct exposure to the eye or deliberate continuous staring can cause eye damage.
  • Page 98 ②Factors affecting measurement results Based on the principle of physics, it cannot be ruled out that there will be error when some specifi c object table is measured. For example: --- A transparent surface (glass, water, etc.), --- Reflective surfaces (polished metal, glass), --- A porous surface (e.g.
  • Page 99 --- Choose a measurement distance that will not change and that you know very well, about 1 to 10 meters long (for example, the width of the room).The measured distance location must be indoors. --- Multiple measurements are made at this distance, and these measurements are then averaged. The measured average distance cannot deviate too far from the actual distance.
  • Page 100 For example, if the red bright spots are not concentrated on a certain point on the surface of the object, but are refracted by the surface of the object to cause red spots on multiple surfaces, the accurate distance value will not be measured, and the test value will not be displayed on the software interface.
  • Page 101: Automatic Lens Calculation Tool

    3.3.33 Automatic Lens Calculation tool Use laser distance measurement, and recommend lenses by testing and monitoring the distance between locations. Put the meter at the position where the surveillance camera needs to be installed, and align the laser ranging module on the top of the meter with the center of the area to be monitored, enter the meter's "automatic lens calculation tool".
  • Page 102: Audio Record

    3. Creating document: Click the “Create Document”, to save the photos and test distance values of the currently tested distance, which is convenient for subsequent viewing. 3.3.34 Audio Record Connect an audio device to the IP tester's audio input port. Click the icon to enter the Audio Recorder app.
  • Page 103: Data Monitor

    3.3.35 Data monitor Please click icon to enter Click "Setting" to choose the baud rate of RS485, it must be the same as the DVR or the Control keyboard. The DVR or Control keyboard send the code to the tester, if it can be read, the protocol will shown on the upper right, like Pelco D, if not, like P:--- While the tester receives the code, press the key to empty.
  • Page 104: Audio Player

    3.3.36 Audio player Click the icon to enter. The audio player only supports MP3 format Audio files. 3.3.37 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV.
  • Page 105: Rtsp Player

    3.3.38 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video.
  • Page 106: Hik Test Tool

    Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera's RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera's user name. IPC Password: Enter the IP camera's password.
  • Page 107 "Activation" and "Batch activation" are optional. Auto open ONVIF protocol: After activation, the new HIK cameras click "play, modify the channel name, modify network information, modify user information" any one of to auto open the selected camera ONVIF protocol. Play: Security status shows the "activated" camera. Enter the correct camera password in the right [password] and click [play] to pop up the "private protocol"...
  • Page 108 Modify channel name: Clicking "Modify the channel name" will pop up OSD settings, including time, channel name and other optional items. After channel selecting, you can edit the channel name, modify the display position, and switch the font size. Select "default location" in "content location" is without modification. Select "Customization" to arbitrarily adjust the channel name and display location.
  • Page 109 and other parameters modification. Enter a new IP address and subnet mask, the default gateway will be auto modified according to the IP address. Click "OK" to save the changes. Page.104.
  • Page 110: Dahua Test Tool

    Modify user information: Modify the camera's user name and password. Factory Reset: Camera factory reset. 3.3.40 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, and modify IP, user name and password etc. Making Dahua camera test more convenient and quickly.
  • Page 111 Activation: select left [online detection] to display the "inactivated" camera and click activate. Activate and Batch activate are optional, support reserved phone number for resetting password. Page.106.
  • Page 112 Play: When mode display "activated" camera, input correct password, click "Play" poping up "private protocol" and "ONVIF", Select correspond protocol to view the camera image. Modify Channel: Click "Modify Channel", will pop up OSD setting, includes time, channel name,etc Page.107.
  • Page 113 After selected Channel name, can edit channel name, modify the display position and font size. If select "Default position" of Content location, then no need to modify. If select "customize", then can modify Channel name and display position, click "OK" to view the image. Click "Back" or "Return" button to return previous interface.
  • Page 114 Input new IP address, need to input password, click "OK" to save the modification Modify user information: Modify camera user name and password, which is onvif, Dahua test tool, IPC TESTE user name and password, not web user name and password. Page.109.
  • Page 115: Update

    Factory reset setting: Camera will be soft reset, and the device's user name, password and network set be saved. Other settings information is factory reset. 3.3.41 Update Copy the downloaded update file to SD card "update" directory, if no directory, please create one. Click the icon to open the Update menu.
  • Page 116: Office

    If there are update programs, applications will be listed in the interface, click related applications, update to the latest version. Update online: Before using online update, need enter settings-user management to register first. System update: Connect the Internet to update systems. 3.3.42 Office Quick office app (support excel, word, ppt format) doc.
  • Page 117: Led Flashlight

    3.3.43 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon enter While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don't press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on.
  • Page 118: Notepad

    camera. If they are not in the same segment, click the button or press "RETRUN" to exit. Open the "Settings" app from the main menu to change the IP tester's network settings to match those of the IP camera. 3.3.45 Notepad Notepad can be used to record the important testing results, click the key "Save"...
  • Page 119: Professional Wifi Analyzer

    3.3.46 Professional WIFI Analyzer Detect the surrounding wifi signal and signal strength, support 2.4G and 5G frequency band. Access point list and List format, display WIFI's channel, frequency, signal strength, device information and distance, etc. Page.114.
  • Page 120: System Setting

    3.3.47 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish, Spanish, French or Japanese, German, Turkish, etc. Typewriting: You can select typewriting or install other typewriting: Date/Time: Set the Date/time of the IP tester IP setting: Manually set the IP address, Subnet Mask, Default Gateway and DNS address or select "Dynamic allocation"...
  • Page 121 click "Add " to enter another IP address for the IP tester. After setting an advanced IP address (refer to the photos above), the unit can test two network segments (192.168.5.0) and (192.168.1.0) WLAN Net: Turn WiFi off or on by pressing the "Open the wifi" button. Once WiFi is turned on, and click connected WIFI, it will scan for wireless networks in your area.
  • Page 122 Wi-Fi hotspot: Input "SSID" name and "password", and then click "ok" to create Wi-Fi hotspot. Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files via FTP Page.117.
  • Page 123 Start the FTP server and then input the tester's FTP address in the PC's address bar. This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader. Version Information: Shows applications version information, if press any apps icon several seconds to uninstall.
  • Page 124: File Explorer

    and write your feedback. Lock Screen: The meter default is not locked. You can choose password Lock screen, pattern Lock screen or "NO". Password Lock Screen: Set password, you can input digitals, letters or characters as password, input it again to confirm .when the meter is in standby mode or turn it on, you can input your password to enter. Pattern Lock Screen: Drawing a pattern to lock.
  • Page 125: Sfp Optical Module Connection

    FTP server You can choose internal or external SD card. Other operation details, Please refer to FTP settings. 3.3.49 SFP optical module connection Connect the SFP optical module to the SFP slot on the top of the instrument, and use the optical fiber jumper to connect the SFP module of the switch or other equipment, to realize the network connection and related network detection.
  • Page 126: Audio Test

    Note: After the SFP optical module is inserted into the tester “SFP” port, please do not look directly at the optical fiber hole of the SFP optical module, to avoid damage eyes caused by the lasers (many lasers are invisible). When not in use, cover the SFP fiber hole with a dust cap to prevent the fiber hole from being damaged by long time exposure.
  • Page 127: Specifications

    4. Specifications 4.1 General Specifications Model IP Camera Tester【*】models Optional Display New 7 inch retina touch screen, 1280*800 resolution Network port 10/100/1000M auto adjust, RJ45, Dual LAN port Built in WIFI, speeds 433M, allows you to connect to a wireless network WIFI and view IP cameras, Operating Frequencies: 2.4G and 5.8G 8K H.265 Mainstream...
  • Page 128 2160P 25/30 fps, UTC control and call OSD menu 1 channel CVI input(BNC interface, resolution support 720P CVI video signal test * 25/30/50/60fps,1080P 25/30fps, 2560x1440P 25/30fps, 2592x1944 20fps, (Optional) 2960x1920 20fps, 3840 x 2160 12.5/15 fps. UTC control and call OSD menu 1 channel TVI input(BNC interfce),resolution support 720P TVI video signal test*...
  • Page 129 25/30fps,1280x720p 25/30fps. CVBS supported: PAL/NTSC。 PEAK video signal level, SYNC signal level, COLOR BURST level Video level meter measurement for CVBS camera. Zoom Image Supports Analog and IP camera image zooming & movement Snapshot, Video Capture current images and record live video as JPG file. Media player will record and playback view photos and playback video HDMI IN, Support 4K 30FPS, 3840x2160P 30FPS, 720×480P...
  • Page 130 Output one channel PAL/NTSC color bar video signal for testing monitor or Color bar generator video cable.(red, green, blue, white and black color ) Test UTP cable connection status and display on the screen. Read the UTP Cable tester number on the screen Captures and analyzes the command data from controlling device, also can Data monitor send hexadecimal...
  • Page 131: Multi-Meter Specifications

    quality of BNC cable. POWER External power DC 12V 2A supply Battery Built-in 7.6V Lithium polymer battery, 7800 mAh Rechargeable Fasting charge, after charging 3.5 hours, normal working time 16 hours Parameter Capacitive touch screen, OSD menu, select your desired language: English, Operation setting Chinese, Korean, Russian, Italian or Polish, etc.
  • Page 132 660.0V 100mV AC voltage Range Accuracy Resolution ±(1.5%+6) 660.0mV (Manual range) 0.1mV 6.600V ±(0.8%+6) 66.00V 10mV 660.0V 100mV DC current Range Accuracy Resolution 6.600mA ±(0.5%+3) 66.00mA 10uA 660.0mA 100uA ±(1%+5) 10.00A 10mA AC current Range Accuracy Resolution 6.600mA ±(0.5%+3) 66.00mA 10uA 660.0mA 100uA...
  • Page 133 66.00KΩ 10Ω 660.0KΩ 100Ω 6.600MΩ 1KΩ 66MΩ ±(1.2%+5) 10KΩ Continuity Range Resolution Function The measurement value less 30Ω±3Ω,the tester will 660.0Ω 0.1Ω sound Diode Range Resolution Function Schottky diode:0.15~0.25V 2.0V rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Capacitance Range Accuracy Resolution ±(0.5%+20) 6.600nF 66.00nF 10pF...
  • Page 134: Optical Power Meter Specifications

    4.3 Optical power meter specifications -70~+10dBm Measure Range(dBm) Wavelength(nm) 850nm,1300nm,1310nm,1490nm,1550nm,1625nm Detector InGaAs <±3%dB(-10dBm,22℃) <±5%dB(full range,22℃) Uncertainly Display Resolution Linear:0.1% ; Nonlinear:0.01dBm -10~+50 Operating Temperature(℃) -20~+70 Storage Temperature (℃) Connector type FC/PC 4.4 Visual fault locator specifications Laser type Wavelength Calibration 650nm Output power 5mW(Optional 10mW,20mW)...