Delta CS-H9-70HG User Manual page 85

Ip camera tester
Table of Contents

Advertisement

range.
c.Manual range: 0.000mA → 6.6mA range
d. Select the range to enter current measurement
NOTE:
◆ When only the figure "OL" is displayed, it indicates over range situation and the higher range has to
be selected.
◆ When the value scale to be measured is unknown beforehand, set the range selector at the highest
position.
◆ The maximum current of mA socket is 660mA, over-current will destroy the fuse, and will damage
the meter.
◆ The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage
the operator.
D. AC Current Measuring (Only Manual range)
WARNING!
Shut down the power of the tested circuit, and then connect the meter with the circuit for
measurement.
a. Connect the black test lead to the "COM" jack and the red test
lead to the"mA" jack for a maximum of 660mA current. For a
maximum of 10A, move the red lead to the 10A jack.
00.00mA → 66.00mA range
000.0mA → 660.0mA range
→ 10.00A range(use 10A socket)
00.00A
Page.80.

Advertisement

Table of Contents
loading