5.5.3. Unclear or not uniform print.
Uneven or bad card surface.
Change the card.
Too high or low setting of the color density.
Please contact the local supplier. The color
density default of your printer needs to be
changed.
The printer head is contaminated with the
dust and dirt.
Clean the printer head with cleaning kit.
5.5.4. Not aligned color print.
Non-standard cards or bad cards.
Change the cards. You can use only ISO CR-80
card (54mm x 86mm).
Uneven or bad card surface.
Change the card.
The transfer roller or printing roller is
contaminated with the dust and dirt.
Clean the rollers with the cleaning kit as section 5.2.
 Worn-out printer.
Please contact the local supplier.
5.5.5. Unplanned color print.
 Non-standard cards or bad cards.
Change the cards. You can use only ISO CR-80
card (54mm x 86mm).
Uneven or bad card surface.
Change the card.
The transfer roller or printing roller is
contaminated with the dust and dirt.
Clean the rollers with the cleaning kit as section 5.2.
 Worn-out printer.
Please contact the local supplier.