MAINTENANCE AND LUBRICATION
Reposition or shield any parts that would be damaged by high temperatures during welding.
Complete the battery cable removal by removing the positive cable last.
•
Attach the welder ground cable as close to the weld area as possible (6 inches or less
from the place being welded).
•
DO NOT connect the welder ground cable near any electronic module, such as the
EECU or its cooling plate.
•
Welding cables should not be allowed to lie on, or run parallel with any wiring.
•
Welding cables should not be allowed to lie near any electronic component during
welding.
•
After welding is complete and the welded areas have cooled, inspect wiring and
components for possible shorts, nicks, abrasion or other damage.
W8003200