– as soon as the symbols begin to flash, release the buttons
and
>
and press the button
– the "Automatic self-calibrating procedure" starts
– open one or more than one hot water tap
– the values flash on the display: "100" (maximum value), fol-
lowed by an "intermediate value" and finally "00" (minimum
value)
The operator must wait for approximately 15 minutes for the
"self-calibrating procedure" to end and the message "SUMMER
mode"
l
to reappear on the display. Once the procedure has
terminated:
– close the taps opened previously and check that the appliance
shuts down.
if there is a fault, the message "ALL" will appear on the display,
the fault code (eg. "06" - no flame detected) and the message
d
.
m
CAUTION
To restore the start conditions press and hold the but-
ton
y
for more than 3 seconds. This operation can
be performed up to a maximum of 6 times without the
"self-calibrating procedure" being interrupted.
– press the button
Y
"WINTER mode"
n
. The value of the heating water tempera-
ture detected at that moment will appear on the display
– adjust the air thermostat and check that the boiler starts and
operates correctly
– carry out the procedure "Chimney sweeper function", to
check the mains gas pressure, detect the combustion param-
eters and to measure the combustion efficiency required by
legislation in force.
44
y
, within 3 seconds
once for at least 1 second to select
6.3
Main control panel display and settings
<
m
CAUTION
We recommend not changing the factory settings so
as not to alter optimal appliance operation. For any
specific support, please contact the Sime Technical
Assistance Service.
6.3.1
Settings using the MODE button
From the "Main screen":
Zone
Menu
– Press the
Mode
lection screen. Turn the
"Winter")
Summer
Hot water
Heating
Holiday function
Esc
– press the
click
encoder to confirm the highlighted "Mode"
and go to the "rows"
Hot water
Heating
Holiday function
Esc
Thu 18 Set 2014
10:30
Off
Mode
button to view the "Function mode" se-
encoder to select a mode (e.g.
Winter
Off
MAN 40°C
MAN 20.0°C
OFF
Back
Winter
MAN 40°C
MAN 20.0°C
OFF
Back
Fig. 100
Fig. 101
Fig. 102