– as soon as the symbols begin to flash, release the buttons
and
>
and press the button
– the "Automatic self-calibrating procedure" starts
– to dissipate the heat , tun on one or more DHW taps
– the values flash on the display: "100" (maximum value), fol-
lowed by an "intermediate value" and finally "00" (minimum
value)
It may take up 15 minutes for the "self-calibrating procedure"
to end and the message "SUMMER mode"
the display Once the procedure has terminated:
– close the taps opened previously and check that the appli-
ance shuts down.
if there is a fault, the message "ALL" will appear on the display,
the fault code (eg. "06" - no flame detected) and the message
d
.
m
CAUTION
To restore the start conditions press and hold the but-
ton
y
for more than 3 seconds. This operation can
be performed up to a maximum of 6 times without the
"self-calibrating procedure" being interrupted.
– press the button
Y
once for at least 1 second to select
"WINTER mode"
n
. The value of the heating water temper-
ature detected at that moment will appear on the display
– operate the heating controls and check that the boiler starts
and operates correctly
– using the procedure shown in section "Chimney sweep func-
tion"complete inlet working gas pressure test and a flue gas
analysis.
y
, within 3 seconds
l
to reappear on
6.3

Main control panel display and settings

<
m
CAUTION
We recommend not changing the factory settings so
as not to alter optimal appliance operation. For any
specific support, please contact the Sime Ltd Techni-
cal Assistance Service.
6.3.1

Settings using the MODE button

From the "Main screen" :
Zone
Menu
– Press the
Mode
lection screen. Turn the
"Winter")
Summer
Hot water
Heating
Holiday function
Esc
– press the
encoder to confirm the highlighted "Mode"
click
and go to the "rows"
Hot water
Heating
Holiday function
Esc
Thu 18 Set 2014
10:30
Off
Mode
button to view the "Function mode" se-
encoder to select a mode (e.g.
Off
Winter
MAN 40°C
MAN 20.0°C
OFF
Back
Winter
MAN 40°C
MAN 20.0°C
OFF
Back
Fig. 102
Fig. 103
Fig. 104