Type
No.
Description
Minimum Heating Temperature
PAR
13
Adjustment
Maximum Heating Temperature
PAR
14
Adjustment
PAR
15
Maximum power heating
PAR
16
Heating Post-Circulation Time
PAR
17
Heating Pump Activation Delay
PAR
18
Re-ignition Delay
Domestic Hot Water Modulation with
PAR
19
Flow meter
PAR
20
Maximum power domestic hot water
Minimum power heating/domestic hot
PAR
21
water (premixed)
PAR
22
Domestic hot water preheating enabling
PAR
23
External relay 1 function
PAR
24
External relay 2 function
Auxiliary TA function
PAR
25
0 = according to TA
PAR
26
Zone Valve / Pump Relaunch Delay
PAR
28
DHW activation delay with solar power
Anti-legionella Function (Only hot water
PAR
29
tank)
-- = Disabled
Maximum domestic hot water
PAR
30
temperature
PAR
35
Digital / analogue Pressure switch
PAR
39
Modulating pump minimum speed
PAR
40
Modulating Pump Speed
PAR
41
∆T Modulating pump delivery/Return
Select heat pump or gas boiler
PAR
42
switchover
Delay boiler activation to boost heat
PAR
43
pump
System pump forcing (only in winter
PAR
47
mode)
PAR
48
INST Parameter set to default
Range
20 .. PAR 14
PAR 13 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
0 = Disabled
1 = Enabled
0 .. 100
0 .. 100
0 = OFF
1 = ON
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
9 = heat pump management
0 = not used
1 = remote alarm NO
2 = remote alarm NC
3 = zone valve
4 = automatic filling
5 = external request
6 = recirculation pump
7 = zone valve with OT
8 = relaunch pump
9 = heat pump management
1 = TA Antifreeze
2= domestic hot water disabled
0 .. 99
0 .. 30
50 .. 80
10 .. 67
0 = water pressure switch
1 = water pressure transducer
2 = water pressure transducer (only pressure
displayed)
20 .. 100
-- = No modulation
AU = Automatic 30 100%
PAR 39 100%
10 .. 40
-20 .. 30
1 .. 180
0 = Disabled
1 = Enabled
RESET
0 .. 1
U/M
Step
Default
°C
1
20
°C
1
65
%
1
100
seconds
1
3
x 10
seconds
1
0
x 10
Min
1
3
-
1
1
%
1
100
%
1
0
-
1
0
-
-
0
-
-
0
-
1
0
Min
1
1
Min
1
0
-
1
--
°C
1
60
-
1
1
%
1
55
%
10
PM
°C
1
20
°C
1
5
Min
1
20
-
-
0
-
-
0
55