5. Remove the stop ring from the forwarding
pulley retainer.
6. Pull the paper forwarding pulley shaft and
remove the forwarding pulley.
Removing the paper feed pulley
7. Remove two stop rings from the primary
paper feed unit.
8. Pull the paper feed pulley shaft in the direc-
tion of the arrow and remove the paper feed
pulley.
Removing the separation pulley
9. Remove the stop ring from the primary
paper feed unit.
10. Pull the separation pulley shaft in the direc-
tion of the arrow and remove the separation
pulley.
Y108620-5
Forwarding
pulley shaft
Forwarding pulley
Paper feed
pulley shaft
Stop ring
Service Manual
Figure 1-5-3
Stop ring
Stop ring
Paper feed pulley
Figure 1-5-4
Separation pulley shaft
Separation pulley
Figure 1-5-5
2H0/2HZ
Stop ring
1-5-3