PED4000/PED5000 Series Exit Devices
with optional connections
Installation Manual
11

910/A, 930/A, 903/A, 905/A (Electromechanical Exit Trim) -

Exit Device to Frame Connection

1. Mount exit device per instruction sheet provided.
2. From outside of door, route Electromechanical ET wire harness through chassis, then plug 2-pin
connector into mating rail harness 2-pin connector. Ensure wires are tucked in to avoid pinching
wires by push bar or chassis mechanism.
3. Wire to the QC12 Hinge pigtail harness 4-pin connector.
4. Ensure proper voltage is being applied to pigtail harness.
5. Plug pigtail harness 4-pin connector into QC12 hinge 4-pin connector.
The DC voltage applied must not exceed 30VDC. If the applied voltage exceeds
Caution:
30VDC, the electromechincal trim motor may be damaged.
6. Test lock – Fail Secure unlocks with 24VDC power applied. Fail Safe locks with 24VDC power applied.
120VAC (L,N,G)
To closed Fire
Alarm Contact
Contact opens, disconnects 24VDC
from Electromechanical Exit Trim
during fire alarm
ElectroLynx Field
(12 wires max)
QC12 Hinge Pigtail
or
15' Frame Harness
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
(-)
Securitron
+24VDC
BPS
24VDC
1AMP
Outside Card
Power Supply
Reader Relay,
or other switch
(by others)
QC12 Hinge
Exit Rail Assembly
Door Harness
3" Typical
Pluggable 8-pin & 4-pin
connectors
C
NC
4, Tan (54- NO)
QC12 Hinge Pigtail or
Electromechanical Exit Trim (ET) wiring:
Fail Safe (wire to C, NC contacts)
Fail Secure (wire to C, NO contacts)
C
NO
Note: The Electromechanical ET
mounts on outside of door
behind the chassis (ET not
shown)
2, Red (ET+)
1, Black, (ET-)
2-pin
connector
Electromechanical Exit Trim (ET)
910/A, 903/A Fail Safe
930/A, 905/A Fail Secure
*
Note: The Electromechanical ET has a wire with
ring terminal that is connected to the Black ET-
wire. The ring terminal must be secured by an ET
mo
21
Connect
4-pin connector
to QC12
15' Frame Harness
Hinge 4-pin
connector
t
FM575 01/23