PED4000/PED5000 Series Exit Devices
with optional connections
Installation Manual

M93 Prefix (Trim Monitor Switch) - Exit Device to Frame Connection

8
NOTES:
Switch contact rating: 1A @ 30VDC.
Wires must be protected from abrasion.
For use with class II circuits only.
Wiring diagram indicates push bar extended.
Rail, raceway, electric hinge and pigtail connector
terminations and wire colors all match.
1, Violet (ET-)
2, Gray (ET+)
3, Pink (M93 COM)
4, Tan (M93 NO)
QC12 Hinge Pigtail or
15' Frame Harness
Wire M93 switch (COM & NO) contacts to monitor
device as required. Note: If M93 NC contact is
required, refer to Appendix A instruction.
Installation Instructions:
1
Mount exit device per instruction sheet provided.
2. From outside of door, route Electromechanical ET wire harness through chassis and door, then plug
3-pin connector into mating rail harness 3-pin connector.
3. Ensure wires are tucked in to avoid pinching wires by push bar or chassis mechanism.
Plug rail connector into raceway connector. Then feed through 1" hole in door. Install rail mounting
4
bracket with two screws supplied. Install rail insert and end cap.
5
Plug raceway connector into electric hinge connector, then feed through door prep. Mount electric
hinge to door.
Go to (A) if wiring now. Go to (B) if wiring is to be done later:
6
(A) Wire frame side wires to wires on pigtail harness as required using connectors allowed by local code.
Plug pigtail harness connector into electric hinge connector. Feed harnesses through frame prep and
mount electric hinge.
(B) Plug pigtail harness connector into electric hinge connector. Feed harnesses through frame prep and
mount electric hinge.
7. Test lock – M93 trim lever monitor switch monitors lever movement. Switch changes state when lever
is rotated.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
1" Ø wire hole
4
6
Connect
5
4-pin connector
to QC12
Hinge 4-pin
connector
1
M93 PED Series Rail with
8-pin connector
M93 PED4000/PED5000 Series
Rail with 8-pin connector
Rail
18
FM575 01/23
Note: The Electromechanical ET
mounts on other side of door
behind the chassis (ET not shown)
5, Green (M93 NC)
4, Yellow (M93 NO)
3, Orange (M93 COM)

Advertisement